Esprit eco

 - 

Installation and Servicing

 

1

 

BOILER COnTROLS

Operation

Winter conditions - i.e. Ch and DhW required.

Ensure the mode knob control (A) is set to winter (   ) 

The boiler will fire and supply heat to the radiators but will give 

priority to DHW on demand.

summer conditions - i.e. DhW only required.

Set the mode knob control to Summer (

 ). 

Set the CH external controls to OFF.

note

. The pump will operate briefly as a self-check once every 24 

hours, regardless of system demand.

Pre-heat is enabled if the pre-heat indicator (F) is lit.  To switch 

pre-heat on or off move the DHW/Pre-heat control knob (B) fully 

clockwise and then return it to the required DHW temperature setting.

Control of water temperature

Domestic hot Water

The DHW temperature is limited by the boiler controls to 

64

o

C maximum at low draw-off rate, adjustable via the DHW 

temperature control (B).
Due to system variations and seasonal temperature fluctuations 

DHW flow rates/temperature rise will vary, requiring adjustment 

at the draw off tap : the lower the rate the higher the temperature, 

and vice versa.

Central heating

The boiler controls the central heating radiator temperature to a 

maximum of 80

o

C, adjustable via the CH temperature control (C).

The boiler is a high efficiency combination boiler which is most 

efficient when operating in condensing mode.

The boiler will operate in this mode if the CH temperature control 

(C) is set to the ‘e’ position (economy mode).  This control should 

be set to maximum for very cold periods.

Weather Compensation

When the Weather Compensation option is fitted to the system 

then the CH Temperature Control (C) becomes a method of 

controlling room temperature.  Turn the knob clockwise to 

increase room temperature and anti-clockwise to decrease room 

temperature.  Once the desired setting has been achieved, leave 

the knob in this position and the system will automatically achieve 

the desired room temperature for all outside weather conditions.

To shut down the boiler

Set the mode knob control to OFF

To relight the boiler

Repeat the procedure detailed in ‘To light the boiler’.

Frost protection

If no system frost protection is provided and frost is likely during 

a short absence from home, leave the heating controls (if fitted) 

at a reduced temperature setting. For longer periods, the entire 

system should be drained.

If the system includes a frost thermostat then, during cold 

weather, the boiler should be turned OFF at the time switch (if 

fitted) ONLY. The mains supply should be left switched ON, with 

the boiler thermostat left in the normal running position.

Boiler Overheat Protection

The boiler controls will shut down the boiler in the event of 

overheating.  Should this occur, a fault code   will be displayed.
Refer to fault chart.

Flame Failure

Should this occur a fault code 

 will be displayed. Refer to fault chart.

Approx. flow temperatures for the boiler thermostat settings are:

 

Knob setting 

Flow Temperature

 

Minimum

 40

o

C

 (104

o

F

)

 

Maximum

 

64

o

C

  (147

o

F

)

continued . . . . . . 

Legend

A.  Mode Control Knob

B.  DHW/Preheat Control Knob

C.  CH Control Knob

D.  Boiler Status

E.  Burner ‘on’ Indication

F.  Pre Heat on/off Indication

G.  Programmer

H.  Pressure Gauge

J. Condensate Drain

A

B

C

D

G

H

J

E

F

19

20

21

22

23

24
1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

00

I

preheat

preheat

min

min

max

mode

reset

off

status

burner

max

e

Esprit

eco

Summary of Contents for Esprit eco 30

Page 1: ...reverse of book When replacing any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or c...

Page 2: ...gistered Engineer in accordance with the above regulations In IE the installation must be carried out by a Registered Gas Installer RGII and installed in accordance with the current edition of I S 813...

Page 3: ...the system then the CH Temperature Control C becomes a method of controlling room temperature Turn the knob clockwise to increase room temperature and anti clockwise to decrease room temperature Once...

Page 4: ...o be made before it fully defrosts Warm water can also be poured onto the pipe from a watering can or similar DO NOT use boiling water 3 Caution when using warm water as this may freeze and cause othe...

Page 5: ...Note The segment dial can be turned when the time controller is operating In case of power failure re adjust the time controller to the correct time of day turning the dial in a clockwise direction Pe...

Page 6: ...boiler operate and provide central heating Check the time settings on the programmer are as you require and adjust if necessary Check the timer is in an ON position and the room thermostat is turned u...

Page 7: ...call for central heating but the appliance has reached the desired temperature set on the boiler The boiler has a call for hot water but the appliance has reached the desired temperature set on the b...

Page 8: ...LER DESCRIPTION Low Water Pressure ACTION Check system pressure is between 1 1 5bar on the pressure gauge If the boiler fails to operate then please contact Ideal Boilers if under warranty or alternat...

Reviews: