Esprit eco

 - 

Installation and Servicing

Outside Sensor Failure

Reset the appliance - if the boiler fails to operate then please contact 

Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered 

Engineer if outside of the warranty period.  In IE contact a Registered 

Gas Installer (RGII).

Low Mains Voltage

Contact a qualified electrician or your electricity provider.

Unconfigured PCB

Unconfigured PCB.  Please contact Ideal Boilers (if under warranty) or 

alternatively a Gas Safe Registered Engineer if outside of the warranty 

period.  In IE contact a Registered Gas Installer (RGII).

5 Boiler Resets in 15 minutes

1. Turn power off and on at the fused spur.
2. 

If the boiler fails to operate please contact Ideal Boilers (if under 

warranty) or alternatively a Gas Safe Registered Engineer if outside of 

the warranty period.  In IE contact a Registered Gas Installer (RGII).

False Flame Lockout

Reset the appliance - if the boiler fails to operate then please contact 

Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered 

Engineer if outside of the warranty period.  In IE contact a Registered 

Gas Installer (RGII).

BCC Activation Fault

Reset the appliance - if the boiler fails to operate then please contact 

Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered 

Engineer if outside of the warranty period.  In IE contact a Registered 

Gas Installer (RGII).

DIspLay CODE ON BOILER

DEsCRIpTION

Low Water Pressure

aCTION

Check system pressure is between 1 & 1.5bar on the pressure gauge.  

If the boiler fails to operate then please contact Ideal Boilers (if under 

warranty) or alternatively a Gas Safe Registered Engineer if outside of 

the warranty period.  In IE contact a Registered Gas Installer (RGII).

Flame Loss

Ignition Lockout

1. Check other gas appliances in the house are working to confirm a 

supply is present in the property.

2. If other appliances do not work or there are no other appliances, 

check the gas supply is on at the meter and/or pre payment meter 

has credit.  If the boiler fails to operate then please contact Ideal 

Boilers (if under warranty) or alternatively a Gas Safe Registered 

Engineer if outside of the warranty period.  In IE contact a Registered 

Gas Installer (RGII).

Fan Fault

Reset the appliance - if the boiler fails to operate then please contact 

Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered 

Engineer if outside of the warranty period.  In IE contact a Registered 

Gas Installer (RGII).

Flow Thermistor

Reset the appliance - if the boiler fails to operate then please contact 

Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered 

Engineer if outside of the warranty period.  In IE contact a Registered 

Gas Installer (RGII).

Return Thermistor

Reset the appliance - if the boiler fails to operate then please contact 

Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered 

Engineer if outside of the warranty period.  In IE contact a Registered 

Gas Installer (RGII).

FaULT CODEs

Flow Temperature Overheat 

BCC Fault

Summary of Contents for Esprit eco 30

Page 1: ...reverse of book When replacing any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or c...

Page 2: ...gistered Engineer in accordance with the above regulations In IE the installation must be carried out by a Registered Gas Installer RGII and installed in accordance with the current edition of I S 813...

Page 3: ...the system then the CH Temperature Control C becomes a method of controlling room temperature Turn the knob clockwise to increase room temperature and anti clockwise to decrease room temperature Once...

Page 4: ...o be made before it fully defrosts Warm water can also be poured onto the pipe from a watering can or similar DO NOT use boiling water 3 Caution when using warm water as this may freeze and cause othe...

Page 5: ...Note The segment dial can be turned when the time controller is operating In case of power failure re adjust the time controller to the correct time of day turning the dial in a clockwise direction Pe...

Page 6: ...boiler operate and provide central heating Check the time settings on the programmer are as you require and adjust if necessary Check the timer is in an ON position and the room thermostat is turned u...

Page 7: ...call for central heating but the appliance has reached the desired temperature set on the boiler The boiler has a call for hot water but the appliance has reached the desired temperature set on the b...

Page 8: ...LER DESCRIPTION Low Water Pressure ACTION Check system pressure is between 1 1 5bar on the pressure gauge If the boiler fails to operate then please contact Ideal Boilers if under warranty or alternat...