3
Concord CXi -
Installation
CONTENTS
Air Supply
. ........................................................................
9
Boiler Assembly - exploded view
. ...............................
10
Boiler Clearances
. ...........................................................
6
Burner Assemblies - exploded views
. .............................
CXi 110-160
. ..............................................................
29
CXi 180
. .....................................................................
30
Casing Assembly
. ..........................................................
14
Chimney System
. .............................................................
9
Commissioning
. .............................................................
20
Electrical Connections
. .................................................
17
Electrical Supply
. .............................................................
9
Fault Finding
. .................................................................
33
Gas Safety Regulations
...................................................
3
Gas Supply
. .......................................................................
9
Hydraulic Resistance
. ......................................................
6
Initial Lighting
. ................................................................
20
Installation
. .....................................................................
10
Mandatory Requirements
. ...............................................
8
Option Kits
. .......................................................................
5
Pump
. ................................................................................
7
Servicing
. ........................................................................
27
Short List of Parts
. .........................................................
36
Static Head Requirements
. .............................................
7
System Connections
. .....................................................
13
Ventilation
. ........................................................................
9
Water Circulation
. ............................................................
5
Water Connections
. .........................................................
5
Water Treatment
. ..............................................................
7
Wiring Diagrams
. ...........................................................
18
INTRODUCTION
CONSTRUCTION
BOILER BODY
The sectional boiler body is of cast iron and is supplied with a
sheet steel combustion chamber and integral draught diverter. The
boiler is supplied in sectioned form for site assembly.
CASING
The casing is manufactured in stove enamelled sheet steel and is
easily assembled on site.
BURNERS
The 3 burners are of stainless steel construction.
Gas Safety (Installation and Use) Regulations,
1994, amendments 1996 or rules in force.
It is the law that
all
gas appliances are installed and serviced by a
CORGI registered installer (identified by ) in accordance with
the above regulations. Failure to install appliances correctly could
lead to prosecution. It is in your own interest, and that of safety, to
ensure that the law is complied with.
The
Concord CXi 110-180
range
of boilers has been tested and
certified by British Gas to prEN656 for use with
natural gas only.
Note.
Concord CXi 110 - 180
boilers are intended for use as
COMMERCIAL BOILERS and are NOT certified for use in domestic
applications. A domestic installation is defined as an installation
where the boiler takes its combustion air from a living space or
from a room directly or indirectly connected with the living space.
It is important, therefore, that no external control devices - e.g.
flue dampers, economisers etc., are directly connected to this
appliance unless covered by these Installation and Servicing
Instructions or otherwise recommended by
Caradon Plumbing
Limited
in writing. If in doubt please enquire.
Any direct connection of a control device not approved by
Caradon
Plumbing Limited
could invalidate the British Gas Certification,
the normal appliance warranty and could also infringe the Gas
Safety Regulations. Table 1, Table 2 and the descriptive notes
which follow contain all the essential data likely to be required by
the installer.
GAS CONTROLS
The gas controls consist of a high / low arrangement with direct
burner ignition.
ELECTRICAL CONTROLS
WARNING
.
The ON/STANDBY [1/0] button does
NOT
electrically
isolate the boiler.
The
Concord CXi
incorporates an advanced microprocessor-
based control system which operates all electrical functions of the
boiler, including ignition, flame detection, thermostatic control and
high/low operation. In addition, the microprocessor has onboard
servicing and commissioning instructions and a fault diagnosis
programme.
The illuminated LED display gives a continual read-out of the
boiler status and functions but, in the (unlikely) event of a fault
condition, will display the fault areas.
Concord CXi 110-180
(Natural gas)
B.G. Certified
-
P.I. No
.
87/AQ/341
Destination Countries:
GB and IE