GAS LEAK
(usually detected by a distinctive smell)
DO NOT use electrical switches
DO NOT look for a leak with a naked flame
IMMEDIATE ACTION:
•
CLOSE
all supply valves.
•
EXTINGUISH all sources of ignition.
•
Open all doors and windows.
•
If leakage cannot be stopped REMOVE CYLINDERS to
a safe place in the open air and advise the supplier. If
this is not possible, evacuate the premises and call the
fire brigade.
•
Do not use the installation until it has been checked by a
CORGI registered installer.
EMERGENCY ACTION
EMERGENCY ACTION
FIRE
IMMEDIATE ACTION:
IF SAFE TO DO SO
, SHUT OFF THE GAS SUPPLY
Do not attempt to extinguish gas flame by any other means.
Raise the alarm and call the fire brigade
stating that a
liquefied petroleum gas cylinder is involved, and give its location.
DO NOT GO NEAR A CYLINDER if a cylinder is being heated
by fire.
ALERT EVERYONE in the immediate area of the fire and
evacuate the building.
ADVISE THE FIRE BRIGADE on their ARRIVAL of the
LOCATION of the cylinder.
If a cylinder is not involved in the fire and it is SAFE TO DO
SO, close all cylinder valves and remove the cylinders to a
safe place.
6
6
6
6
6
CARADON PLUMBING Ltd.
, P.O. Box 103, National
Ave, Kingston upon Hull, HU5 4JN. Telephone: 01482
492 251 Fax: 01482 448 858. Registration No. London
322 137. Registered Office: National Avenue, Kingston
upon Hull, HU5 4JN.
A subsidiary of Caradon plc.
September 1999
112 561 A03
The code of practice for the installation,
commissioning & servicing of central heating systems
Caradon Plumbing Limited is a member of the Benchmark
initiative and fully supports the aims of the programme.
Benchmark has been introduced to improve the standards of
installation and commissioning of central heating systems in
the UK and to encourage the regular servicing of all central
heating systems to ensure safety and efficiency.
Ideal Consumer Helpline: 01482 498660
CARADON PLUMBING Ltd.
pursues a policy of continuing
improvement in the design and performance of its products. The
right is therefore reserved to vary specification without notice.
The Gas Safety (installation & Use) Regulations, Statutory
Instrument 1994, No. 1886,
impose certain legal obligations on
gas users.
CHANGING GAS CYLINDERS
a.
Ensure that the replacement gas cylinder is the correct one for
the installation.
b.
Extinguish any fire, flame or source of ignition (including cigarettes,
pipes and pilot lights) before changing the gas cylinders.
c.
Change cylinders with caution.
d.
Ensure that the gas cylinder valve(s) is/are closed before
disconnecting an empty cylinder or before removing any plastic
cap or plug on the outlet connection of the replacement cylinder.
Never use tools on cylinder valves, hand wheels or levers.
Note.
Cylinders with threaded connections have a left hand thread.
For cylinders with self-sealing clip-on valves, ensure that the
regulator tap is closed before disconnection.
e.
Ensure that the replacement cylinder connections are gastight.
Any leaking vapour will have a distinctive odour. Test by using
leak detection solution around the connections - bubbles will form
if vapour is leaking.
NEVER USE A NAKED FLAME
f.
It is essential that the correct pressure regulator, with the correct
pressure setting and capacity for the installation, is used in
accordance with the manufacturer's instructions.
g.
In the case of a connection on a pressure regulator or gas
appliance which relies upon a sealing washer to maintain a
gastight joint, it is essential to check that the washer is present
and that it is sound and correctly positioned prior to making the
connection. Where the connection relies on a metal-to-metal
seating or bullnose connection to obtain a gastight joint, it is
essential that the mating surfaces be clean and undamaged.
Under no circumstances should a damaged valve or connection
be used.
h.
Where connections are designed to be tightened with a spanner,
it is essential that a spanner of the correct size is used and that
the union is firmly tightened - hand tightness is not sufficient.
When self sealing valves are incorporated in a gas cylinder,
connection should be made in accordance with the manufacturer's
instructions and tools should not be used.
i.
If the continuation of supply is interrupted when a cylinder is
changed, it is essential that all appliance taps are turned off before
the change is made.
j.
With bulk storage tanks always ensure that the site is kept clean
and clear of rubbish. Such vessels are designed to be filled on
site by the gas distributors.