14

3.  dB and dBm (ACV / ACmV only)

4.  Relative mode

In the relative mode, the meter records the current input value as 

reference and appears on the upper display. The after input values 

will calculate the difference (     ) of the reference value and the input 

value or the difference percent (%) of the reference value and the 

input value.

The decibel (dB) is a logarithmic unit of measurement that expresses 

the magnitude of a physical quantity relative to a specified or implied 

reference level. The dB and dBm are defined below.

 dB = 20 log 

 

dBm = 20 log 

 

V

AC

1

V

AC

0.7746

AC

AUTO

kHz

V

ENTER

CANCEL

PRESS

PRESS

PRESS

dB

dBm

AC

AUTO

dB

V

dB

dB

AC

AUTO

dB

V

dBm

dBm

dB

dBm

AC

AUTO

V

ENTER

PRESS

CANCEL

PRESS

AC 2V

PRESS

AC

V

V

AC

V

V

OFF

MAX

10A

FUSED

MAX

mA

FUSED

600V

CAT IV

1000V

CAT III

A

mA COM V

Hz °C

°C°F

V

Hz%

mV

A

AC 3V

OFF

MAX

10A

FUSED

MAX

mA

FUSED

600V

CAT IV

1000V

CAT III

A

mA COM V

Hz °C

°C°F

V

Hz%

mV

A

AC 3V

OFF

MAX

10A

FUSED

MAX

mA

FUSED

600V

CAT IV

1000V

CAT III

A

mA COM V

Hz °C

°C°F

V

Hz%

mV

A

Summary of Contents for 61-497

Page 1: ...pt to repair this unit as it has no user serviceable parts CAUTION To protect yourself think Safety First Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution Use appropriate personal...

Page 2: ...throw away The Meter Description Front Panel Illustration 1 LCD display 4000 40000 counts for 61 497 10000 100000 counts for 61 498 2 Push buttons 3 Rotary switch to turn the Power On Off and select t...

Page 3: ...filter is 800 Hz When the rotary switch is in V mV position the HFR mode can be used To use HFR mode press the HFR button Measuring Resistance Continuity Diode Capacitance kM Hz G F C mVAF ACDC LV Au...

Page 4: ...RS232 HFR OFF MAX 10A FUSED MAX mA FUSED 600V CAT IV 1000V CAT III A mA COM V Hz C C F V Hz mV A A MAX MIN FH AVG AC DC STORE RECALL dB dBm LOG RATE DATA LOG MAX MIN AVG SETUP RANGE DIGIT CANCEL P HOL...

Page 5: ...e difference of the hold value and the current value is above 20 counts the meter beeps and holds the new value To use the Auto Hold mode press the A Hold button kHz AUTO DIGIT Press V AC Press A Hold...

Page 6: ...below the recorded minimum value or above the recorded maximum value the meter records the new value The MAX MIN AVG mode can also calculate the average of the maximum value and the minimum value DC V...

Page 7: ...he magnitude of a physical quantity relative to a specified or implied reference level The dB and dBm are defined below dB 20 log dBm 20 log VAC 1 VAC 0 7746 AC AUTO kHz V ENTER CANCEL PRESS PRESS PRE...

Page 8: ...ETUP Option Press or to change the meter setting Press ENTER to store the setting in memory Press or to select the meter setting item Press CANCEL to exit this function 5 1 Beeper Setup the beeper to...

Page 9: ...to replace the fuse and batteries CAUTION Use only a fuse with the amperage interrupt voltage and speed rating specified Fuse rating 440mA 1000V IR 10KA Fuse size 35 x 10mm 11A 1000V IR 20KA Fuse size...

Page 10: ...Dimensions W x H x D 95mm x 207mm x 52mm with holster Accessories Battery installed Test leads and user manual The probe assembly provided with the product is for use with this meter only Power Requir...

Page 11: ...3KHz 3 00 50d 2 10 0000VAC 100 000VAC 1000 00VAC 40Hz 45Hz 1 00 50d 1 46Hz 65Hz 0 40 50d 1 66Hz 1KHz 1 00 50d 1 10 0000VAC 100 000VAC 1 01KHz 10KHz 2 00 50d 1 10 01KHz 20KHz 3 00 50d 2 20 01KHz 50KHz...

Page 12: ...e the REL function to compensate for offsets Input Protection 1000VDC or 1000VAC rms Maximum Open Circuit Voltage Approximate 2 5V Maximum Test Current Approximate 0 1mA Continuity Threshold Approxima...

Page 13: ...ol indicates that the product is forbidden to be disposed via domestic refuse The chemi cal symbols for the respective hazardous substances are Cd Cadmium Hg Mercury Pb Lead You can return used batter...

Reviews: