Specifications

General Specifications 

Maximum voltage applied 

to any terminal:

1000V ac rms or dc

Display

4000/40000 counts for 61-497

10000/100000 counts for 61-498

Polarity Indication:

OL

Batteries Life:

100 hours

Low Batteries Indication:

“     “ is displayed when the batteries voltage 

drops below operating voltage

Low battery voltage:

Approx. 4.5V

AUto Power Off:

Default 30 minutes

Operating Ambient:

Non-condensing 

 10°C

11°C ~ 30°C (

 80% RH),

30°C ~ 40°C (

 75% RH),

40°C ~ 50°C (

 45% RH),

Storage Temperature:

-20°C to 60°C, 0 to 80% R.H. 

(batteries not fitted)

Temperature oefficient:

0.15 x (Spec. Accy) / °C, < 18°C or > 28°C

Measure

Samples 3 times per second normal

Altitude

6561.7 ft. (2000m)

Safety

Complies with EN61010-1, UL61010-1, 

IEC61010-1, CAT IV 600V, CAT III 1000V

CAT

Application FIeld

I

The circuits not connected to mains

II

The circuits directly connected to 

Low-voltage installation

III

The building installation

IV

The source of the Low-voltage installation

Weight:

(630g) including battery.

Dimensions (W x H x D)

95mm x 207mm x 52mm with holster.

Accessories:

Battery (installed), Test leads and user 

manual. (The probe assembly provided with 

the product is for use with this meter only)

Power Requirements:

1.5V x 4 IEC LR6 or AA size.

Pollution degree:

EMC

EN 61326-1   

Shock vibration:

Sinusoidal vibration per MIL-T- 28800E  

(5 ~ 55 Hz, 3g maximum).

Drop Protection

4 ft. drop to hardwood on concrete floor.

Indoor Use. 

61-497

Range

Frequency

Accuracy

40.000mV

DC

± (0.040% + 40d)

400.00mV

DC

± (0.035% + 20d)

4.0000V

DC

40.000V

DC

400.00V

DC

1000.0V

DC

± (0.03% + 20d)

40.000mV

AC

400.00mV

AC

40Hz ~ 65Hz

± (1.00% + 50d) 

[1]

66Hz ~ 1KHz

± (3.00% + 50d) 

[1]

1.01KHz ~ 3KHz

± (5.00% + 50d) 

[2]

4.0000V

AC

40.000V

AC

400.00V

AC

1000.0V

AC

40Hz ~ 45Hz

± (1.50% + 50d) 

[1]

46Hz ~ 65Hz

± (0.70% + 50d) 

[1]

66Hz ~ 1KHz

± (1.50% + 50d) 

[1]

4.0000V

AC

40.000V

AC

  

1.01KHz ~ 10KHz

± (3.00% + 50d)

 [2]

10.01KHz ~ 50KHz

± (5.00% + 50d)

 [3]

50.01KHz ~ 100KHz

± (10.0% + 50d)

 [3]

Compliance  to  EN  61557  :  IEC61557-1,  IEC61557-2,                                  

IEC61557-4, IEC61557-10

Electrical Specifications

Accuracy is ±(% r number of digits) at 23°C ± 5°C 

< 80%RH. 

  

(1) Voltage 

 

Equipment protected by double insulation.

  

Instrument has been evaluated and complies with insulation  

(overvoltage) catergory IV. Pollution degree 2 in accordance with 

IEC-644. Indoor use.

Summary of Contents for 61-497

Page 1: ...pt to repair this unit as it has no user serviceable parts CAUTION To protect yourself think Safety First Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution Use appropriate personal...

Page 2: ...throw away The Meter Description Front Panel Illustration 1 LCD display 4000 40000 counts for 61 497 10000 100000 counts for 61 498 2 Push buttons 3 Rotary switch to turn the Power On Off and select t...

Page 3: ...filter is 800 Hz When the rotary switch is in V mV position the HFR mode can be used To use HFR mode press the HFR button Measuring Resistance Continuity Diode Capacitance kM Hz G F C mVAF ACDC LV Au...

Page 4: ...RS232 HFR OFF MAX 10A FUSED MAX mA FUSED 600V CAT IV 1000V CAT III A mA COM V Hz C C F V Hz mV A A MAX MIN FH AVG AC DC STORE RECALL dB dBm LOG RATE DATA LOG MAX MIN AVG SETUP RANGE DIGIT CANCEL P HOL...

Page 5: ...e difference of the hold value and the current value is above 20 counts the meter beeps and holds the new value To use the Auto Hold mode press the A Hold button kHz AUTO DIGIT Press V AC Press A Hold...

Page 6: ...below the recorded minimum value or above the recorded maximum value the meter records the new value The MAX MIN AVG mode can also calculate the average of the maximum value and the minimum value DC V...

Page 7: ...he magnitude of a physical quantity relative to a specified or implied reference level The dB and dBm are defined below dB 20 log dBm 20 log VAC 1 VAC 0 7746 AC AUTO kHz V ENTER CANCEL PRESS PRESS PRE...

Page 8: ...ETUP Option Press or to change the meter setting Press ENTER to store the setting in memory Press or to select the meter setting item Press CANCEL to exit this function 5 1 Beeper Setup the beeper to...

Page 9: ...to replace the fuse and batteries CAUTION Use only a fuse with the amperage interrupt voltage and speed rating specified Fuse rating 440mA 1000V IR 10KA Fuse size 35 x 10mm 11A 1000V IR 20KA Fuse size...

Page 10: ...Dimensions W x H x D 95mm x 207mm x 52mm with holster Accessories Battery installed Test leads and user manual The probe assembly provided with the product is for use with this meter only Power Requir...

Page 11: ...3KHz 3 00 50d 2 10 0000VAC 100 000VAC 1000 00VAC 40Hz 45Hz 1 00 50d 1 46Hz 65Hz 0 40 50d 1 66Hz 1KHz 1 00 50d 1 10 0000VAC 100 000VAC 1 01KHz 10KHz 2 00 50d 1 10 01KHz 20KHz 3 00 50d 2 20 01KHz 50KHz...

Page 12: ...e the REL function to compensate for offsets Input Protection 1000VDC or 1000VAC rms Maximum Open Circuit Voltage Approximate 2 5V Maximum Test Current Approximate 0 1mA Continuity Threshold Approxima...

Page 13: ...ol indicates that the product is forbidden to be disposed via domestic refuse The chemi cal symbols for the respective hazardous substances are Cd Cadmium Hg Mercury Pb Lead You can return used batter...

Reviews: