current standards and certified by the CE directive
up to the TH400 connector (Fig. 3).
The power cable must not be less than type H05VV-
F tripolar with a section of at least 1.5 mm
2
.
To connect the power cable to the TH400 con-
nector remove “A” and “B” (1), loosen “C” (2) and
push pump cable “D” outwards so the terminal
comes out (3). Insert the power cable “E” through
“A” and “B” by connecting the conductors to the
terminals L, N and
(4). Upon completion of
connections, put the terminal back in place, and
tighten “B”, “C” and “A”.
A
B
C
D
L
N
N
L
E
1
2
3
4
fig.3
e
quIPotentIal
connectIon
The whirlpool tub must be connected to the equi-
potential system of the building by a cable with a
section of 2,5÷6mm
2
. Connection is performed by
means of the terminal marked with
, located on
the metallic support (fig.4).
220 V 60 Hz
230 V 50 Hz
fig.4