33
USO
- USE
- UTILISA
TION
- GEBR
AUCH
- USO
- GEBR
UIK
- ΧΡΗΣΗ
ЭК
СПЛУ
АТ
АЦИЯ
- POUŽITÍ
- POUŽITIE
- UPOR
AB
A -
UPO
TREB
A
FIxED AND ALTERNATE BUMPING
FUNCTION
Meaning of LED status
Phase
led
status
Selection/Operation
Fixed bumping
bumping LED blue
steady
Bumping operation
Alternate
Bumping LED flashing
blue
WHEN THE BUMPING KEY IS PRESSED:
- if the system is standing by for the pipe drying
cycle, bumping sill not be activated;
- If the system is at reset and has already run the
automatic pipe drying cycle, bumping will be
activated;
- if there are functions active (0/I LED with
steady green light), the fixed bumping function
starts;
- if no functions are active (0/I LED with steady
red light), press the 0/I key within 5 seconds
(otherwise the bumping LED shuts off ) so that
the 0/I key LED comes on steady green and the
fixed bumping function starts;
- if the fixed bumping function is active, the
alternating bumping function is activated;
THE FUNCTION MAY BE TERMINATED (THE LIGHT
LED GOES OFF):
- on command by the user (pressing the bump-
ing key, if the alternating bumping function is
active, pressing the 0/I key);
- when the function expiration time is up (10
minutes);
- if, during operation, an insufficient level of water
is detected in the tub for more than 3 seconds.
This is only if during the bumping function the
water level sensor in the tub has detected the
presence of water.
AUTOMATIC PIPE DRYING FUNCTION
Meaning of LED status
Phase
led
status
Selection/Operation
drying LED
airpool blue flashing
With system in standby status.
5 minutes after the tub is emptied, that is, when the
level sensor no longer detects water, the blower
automatically starts for roughly 30 seconds. This
makes it possible for the water to leave the pipes.
This same operation can be performed manually,
again with the tub empty, by pressing the “AIRPOOL”
key followed by the 0/I key.
In both cases, the keyboard controls remains ac-
tive.
Manual activation of the function overrides auto-
matic activation. This occurs when you are waiting
for the 5 minutes to elapse and the function is
activated manually.
THE FUNCTION MAY BE TERMINATED (THE LIGHT
LED GOES OFF):
- by user command, pressing the airpool key;
- by user command, pressing the 0/I key;
- when the function timeout has expired (30
seconds);
SySTEm ShUTdOwN
- To interrupt, press the 0/I button.
- At the conclusion of the whirlpool, place the
omnipolar switch back in position “O”.
TT0283660_05_PREMIUM_CMYK.indd 33