background image

IMPORTANT SAFEGUARDS:

When using electrical products, especially when children are present,

basic safety precautions should be followed, including the following:

READ ALL INSTRUCTIONS BEFORE USING

1.  

SAFETY

 

DANGER

 - To reduce the risk of electrocution:

 

- Always unplug this product immediately after using.

 

- Do not use while bathing.

 

- Do not place or store product where it can fall or be pulled into a tub or sink.

 

- Do not place in or drop into water or other liquid.

 

- Do not reach for a product that has fallen into water. Unplug immediately.

 

 

WARNING

 - To reduce the risk of burns, electrocution, fire or injury to persons.

 

- A product should never be left unattended when plugged in.

 

- Close supervision is necessary when this product is used by, on, or near children or invalids.

 

- Use this product only for its intended use as described in this manual.

    

  Do not use attachments not recommended by the manufacturer.

 

- Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or

    

  damaged, or dropped into water. Return the product to a service center for examination and repair.

 

- Keep the cord away from heated surfaces.

 

- Never use while sleeping or drowsy.

 

- Never drop or insert any object into any opening or hose.

 

- Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being 

 

   administered.

 

- Connect this product to a properly grounded outlet only. See Grounding Instructions.

 

- DO NOT IMMERSE. NE PAS IMMERGER.

                                         

 

 

 

 

  

   

SAVE THESE INSTRUCTIONS

 

2.  

MAINTENANCE AND SERVICE

 

The Ideal Gel Warmer does not require routine maintenance.

2.1 

Cleaning

 

Unplug the power cord prior to cleaning. The outer casing my be cleaned with water and a damp cloth. Do not    

 

submerge or immerse the unit in water.

2.2 

Internal Thermal Fuse

 

There is a thermal fuse located inside the unit. The fuse is not replaceable by the operator. If the Ideal Gel  

 

 

Warmer does not operate when plugged into the correct voltage power supply, the unit must be returned to Ideal    

 

for replacement of the thermal fuse. Servicing should be performed by an authorized service representative.

2.3 

Storage

 

When storing warmer, be sure to keep it in a dry area. Coil the cord and secure.

Thank you for choosing an Ideal Bottle Warmer!

3.  

ASSEMBLY

3.1 

Installation

 

The Ideal Gel Warmer can be mounted to a wall or placed on a flat, stable surface. Plug the power cord into a 

 

power supply that matches the voltage listed on the electrical information label on the back of the unit.

3.2 

Wall Mounting

 

The Ideal Gel Warmer can be mounted to a wall using the keyhole slots on the back of the unit. Use mounting

 

hardware capable of supporting a minimum of 15 pounds.

3.3 

Grounding Instructions

 

This product should be gounded. In the event of an electrical short circuit, grounding reduces the risk of electric 

 

shock by providing an escape wire for the electric current. This product is equipped with a cord having a 

 

grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and 

 

grounded.

 

DANGER

 - Improper use of the grounding plug can result in a risk of electric shock

 

If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade 

 

terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the  

 

grounding wire. Check with a qualified electrician or serviceman if the grounding instructions are not completely

  

understood. This product is for use on a nominal 120 V circuit, and has a grounding plug that looks like the plug 

 

illustrated in sketch A in Figure 1. A temporary adapter, which looks like the adapter illustrated in sketches B and 

 

C, may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is

 

unavailable. The temporary adapter should be used only until a properly grounded outlet (sketch A) can be 

 

installed by a qualified electrician. The green colored rigid ear, lug, and the like extending from the adapter must

 

be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adapter is 

 

used, it must be held in place by the screw.

 

If it is necessary to use an extension cord, use only a three wire extension cord that has a three-blade grounding

 

pluf, and a three-slot receptacle that will accept the plug on the product.

4.  

OPERATION

4.1  

Controls and Indicator Lamps 

 

The Indicator Lamp located in the front rocker switch is illuminated when the unit is operating.

 

The Temperature Adjustment Knob allows adjustment of the operating temperature.

4.2 

Setting the Operating Temperature

 

If a change in operating temperature is required, turn the knob clockwise to increase temperature.

 

Turn the screw in small increments and allow sufficient time for the temperature to change.

4.3 

Operating the Gel Warmer

 

Allow sufficient time for the gel or lotion to reach optimum temperature. Gels and lotions at room temperature

 

 may take up to 45 minutes to reach a comfortable temperature.

5.  

TECHNICAL SPECIFICATIONS

 

This devices is intended for indoor use and will meet its operating performance within the ambient temperature  

 

range of 70°F to 90°F.

 

Specifications:

 

 

Supply Voltage Range:   

120V, 60 Hz

 

 

Power Rating:   

 

Model GW108, GW116, EBW-1:  

 125W

 

 

 

 

 

 

Model GW208.1, GW216.1, EBW-2.1:     63W 

 

 

 

 

 

 

Model GW308.1, GW316.1, EBW-3.1:     42W 

 

 

 

 

 

 

Model GW408.1, GW416.1, EBW-4.1:     32W 

Reviews: