Fig 50 shows the result screen of a successful Web test.
Frame Size
and
Frame Fill
are fixed, and stated for reference
only. The Information rate,
IR (Mb/s)
, is variable and
dependent on the number of sessions you have entered at set
up.
Tx
states the number of frames transmitted, the green
indicator bar confirms that 100% of the frames were sent.
Rx
states the number of frames received, the green indicator bar
confirms that 100% of the transmitted frames were received.
As all transmitted frames were received,
Error
states 0 and its
associated indicator bar remains uncolored and shows 0%.
Because the number of errors does not exceed the limit set in
SETUP, the test result is PASSED.
Fig 50
Video
Fig 51 shows the result screen of a successful Video test.
Frame Size
and
Frame Fill
are fixed, and stated for reference
only. The Information rate,
IR (Mb/s)
, is variable and
dependent on the number of streams entered and the
definition (SD- Standard Definition / HD – High definition)
chosen at set up.
Tx
states the number of frames transmitted,
the green indicator bar confirms that 100% of the frames were
sent.
Rx
states the number of frames received, the green
indicator bar confirms that 100% of the transmitted frames
were received. As all transmitted frames were received,
Error
states 0 and its associated indicator bar remains uncolored
and shows 0%. Because the number of errors does not exceed
the limit set in SETUP, the test result is PASSED.
Fig 51
CCTV
Fig 52 shows a CCTV performance test in progress.
Frame
Size
and
Frame Fill
are fixed, and stated for reference only.
The Information rate,
IR (Mb/s)
, is variable and dependent on
the Resolution (VGA / 720p / 1080p / 3MP / 5Mp), CODEC
(H.264 / MJPEG) and number of cameras chosen at set up.
Tx
shows that, so far, 72,371 frames have been transmitted which
is 92% of the total frames required to be sent in this test.
Rx
shows that only 62,405 of the transmitted frames have been
received (79% of the total sent so far).
Error
shows the
number of errored (unreturned) frames (Approx. 12%).
When the number of errored frames is
≥
the Limit (Frames)
that you entered at set up, the test is failed.
Fig 52