SignalTEK NT
156875 Iss 3
User Guide
Page 16
IP Tests continued
Scan Range
Max Number of Hosts
Test time
Class C/24
256
Short
Class C/20
4096
Medium
Class B/16
65,536
Long
IPv6 Netscan Setup – None required (Automatically set).
Select PoE or PoE Plus to suit your network.
Set minimum power to be detected to suit the demand of your appliance.
Set the target URL/Numerical address (select from up to 10 targets stored in
the v6 TARGET look up table or edit the currently displayed URL),
Count (Number of times to repeat the Ping - 1 to 999999),
Pause (Interval between successive Pings - 1 to 5 seconds),
Length (Number of bytes in the Ping frame payload - 8 to 1000 bytes).
Set the target URL/Numerical address (select from up to 10 targets stored in
the v6 TARGET look up table or edit the currently displayed URL),
Maximum number of hops (1 to 30),
Timeout (Abort timeout for any hop - 2 to 30 secs),
Select Name Lookup if supported by your network. If not required, de-select
Name Lookup to reduce test time.
The five performance tests that follow are available:
Tick IEEE802.3 check box to set the frame failure threshold to 0 and the test
duration to 10 secs. With the tick box unchecked the frame failure threshold
and duration can be set manually to suit your test. The frame size is
permanently set to 1518. Frame fill is always fixed. Select the expected Line
Rate depending on the cable type.
No. of Calls (Set expected number of simultaneous calls on the network – 1 to
10,000),
Threshold (Frames) (Enter the number of errored frames acceptable – 0 to
99),
Duration (Set test duration from 1 second up to 24 hrs).
No. of sessions (Set expected number of simultaneous sessions on the network
– 1 to 500),
Threshold (Frames) (Enter the number of errored frames acceptable – 0 to
99),
Duration (Set test duration from 1 second up to 24 hrs).
Definition (Set to HD or SD),
No. of Streams (Set expected number of simultaneous calls on the network – 1
to 70),
Threshold (Frames) (Enter the number of errored frames acceptable – 0 to
99),
Duration (Set test duration from 1 second up to 24 hrs).
Resolution (Set to VGA, 720p, 1080p, 3MP or 5MP),
CODEC (Set to H.264 or MJPEG),
No. of Cameras (Set the number of cameras in the system),
Threshold (Frames) (Enter the number of errored frames acceptable – 0 to
99).