1.8  DISPLAY FUNCTIONS - FAULT MESSAGES

1   With boiler off & system cold, fill system  

 

to 1.0bar.

2   Bleed radiators, refill system to 1.0bar.
3   Check radiator valves & boiler valves are  

 open.

4   Restart boiler.

5   If fault persists contact installer.

 

Restart

Menu

Overheat Lockout

1  Check other gas appliances work.

2  Restart boiler.

3  If fault persists, contact installer.

 

Restart

Menu

Ignition Lockout

Contact Installer

 

 

Menu

Flame Loss

Contact Installer

 

Menu

Too Many Restarts

Contact Installer

 

Restart

Menu

      Flame On Before Gas On

Contact Installer

 

Restart

Menu

Flow Thermistor Fault

Contact Installer

 

 

Menu

Outside Sensor Fault

Contact Installer

 

Restart

Menu

  Return Thermistor Fault

Contact Installer

 

 

Menu

Fan Fault

Contact Installer

 

Menu

PCB Fault

Contact electricity provider

 

Menu

Low Mains Voltage

Contact Installer

 

 

Menu

Flow/Return Reversed

Contact electricity provider

 

Restart

Menu

Gas Valve Fault

1   Check if condensate pipe
     blocked/frozen

2   Check if flue blocked

3   If fault persists, contact installer

 

Restart

Menu

     Blocked Flue/Condensate

Check room thermostat batteries

 

Menu

 Room Thermostat Fault

Contact Installer

 

Menu

Spare PCB Not Set

1 With boiler off & system cold,
   fill system to 1.0bar.
2 Bleed radiators, refill system to 1.0bar.

3 If fault persists, contact installer.

 

 

Menu

No Water Flow

Summary of Contents for LOGIC MAX HEAT2 H12

Page 1: ...we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Heating For the very latest copy of literature for specification and maintenance practices visit our website idealheating com where you can download the relevant information in PDF format USER GUIDE LOGIC MAX HEAT2 H12 H15 H18 H24 H30 October 2022 UIN 228292 A05 ...

Page 2: ...installed Due to the high efficiency of the boiler condensate is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe at the base of the boiler A condensate plume will also be visible at the flue terminal Safety Current Gas Safety Installation Use Regulations or rules in force It is the law that this appliance installation and any work carried ...

Page 3: ...Mode until either Ready or On is shown under the Boiler symbol If Tap Radiators symbols are shown then press Mode until Ready or On is shown under the radiator and tap symbol The boiler will fire and supply heat to the radiators Summer Conditions Domestic Hot Water only required If a Boiler symbol is shown on the display then central heating must be disabled at the timer or room thermostat If Tap ...

Page 4: ...liance is fitted with a siphonic condensate trap system that reduces the risk of the appliance condensate from freezing However should the condensate pipe to this appliance freeze please follow these instructions a If you do not feel competent to carry out the defrosting instructions below please call your local Gas Safe Registered installer for assistance b If you do feel competent to carry out t...

Page 5: ...ctions section Does the boiler have a display showing on the front control panel If fault persists contact Ideal Customer Service Helpline if your appliance is under warranty or a Gas Safe Registered engineer otherwise YES NO Contact a Gas Safe Registered Engineer 1 5 GENERAL INFORMATION Contact a Gas Safe Registered Engineer Contact a Gas Safe Registered Engineer NO YES NO MINIMUM CLEARANCES Clea...

Page 6: ...at 60 C Menu Mode Ready On Radiator Target 60 C Room Thermostat or Timer Off Preheat Active Summer Mode No Heat Demand Target 60 C Menu Mode Off On To Switch On Press Mode Button then On Ready Summer Mode DHW Demand Target 60 C Menu Mode On On at 60 C Winter Mode No Heat Demand Target 60 C Menu Mode Ready Off Radiator Target 60 C Room Thermostat or Timer Off Ready Off To Switch On Press Mode Butto...

Page 7: ...r Restart Menu Flow Thermistor Fault Contact Installer Menu Outside Sensor Fault Contact Installer Restart Menu Return Thermistor Fault Contact Installer Menu Fan Fault Contact Installer Menu PCB Fault Contact electricity provider Menu Low Mains Voltage Contact Installer Menu Flow Return Reversed Contact electricity provider Restart Menu Gas Valve Fault 1 Check if condensate pipe blocked frozen 2 ...

Page 8: ...deal Technical Helpline 01482 498663 Ideal Consumer Helpline 01482 498660 Ideal Parts 01482 498665 idealheating com Ideal Boilers Ltd pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice At Ideal Heating we take our environmental impact seriously therefore when installing any Ideal Heating prod...

Reviews: