47
Installation and Servicing
Section 3 - Servicing
SER
VICING
3.24 REPLACEMENT OF DHW THERMISTOR
1. Isolate the DHW system
2. Remove the retaining clip and extract the thermistor.
Be prepared for some water release.
3. Disconnect the wiring harness.
Refer to Section
3.2
DHW Thermistor position
4. Fit the replacement thermistor and reassemble.
5. Reestablish the DHW supply, turn on a hotwater tap
checking for leaks
1. Drain the boiler.
2. Remove condensate trap.
3. Remove the 2 hex screws securing the plate heat
exchanger to the composite housings.
4. Manoeuvre the plate heat exchanger out of the top LH
or centre of the controls area. Be aware of any water
spillage.
3.25 DHW PLATE HEAT EXCHANGER REPLACEMENT
5. Fit the new plate heat exchanger, using the new o-rings
supplied.
Note.
Ensure that the depressions are on the bottom
prior to fitting.
6. Refill the boiler.
Refer to Section
2.17
Refer to Section
3.2
Refer to Section
3.3
Refer to Section
3.10
3
SCAN
for video
2