Section 5 - Commissioning
COMMISSIONING
50
Installation and Maintenance
5.7 HEAT PUMP CONTROL SETUP
The Heat Pump controls are located on the front of the control
box. This is the centralised control for the full heating system.
ⓘ
IMPORTANT: To use the control screen the dial can
be rotated clockwise to move selection downwards, anti-
clockwise to move selection upwards, and pressed to
select. When options are selected, the dial can be turned
to cycle through the setting options. To exit menus or
return to previous screens, a selectable option will be
displayed at the bottom of the screen.
NAVIGATION SYMBOLS
Default Screen
Space Heating
Domestic Hot Water
System Information
Settings Menu
Return to Previous Screen
Test Function
Installer Functions
OPERATING MODES
Operating Temperatures
Water Flow from Heat Pump to Indoor Unit
Heat Pump Output
Hot Water and Central Heating System Control
Actuator Status
5
Details on Immersion Heater - On/Off
5.7.1 Initial Heat Delivery
CREATING A CENTRAL HEATING DEMAND
If a halo is used consult the Halo instruction manual.
On/Off Room Stat Increase the room temperature setpoint until
the heating switches on
SWITCHING CENTRAL HEATING OFF
Switch central heating off using Halo or On/Off room stat
CREATING A HOT WATER DEMAND & CHANGING THE
SETPOINT
20.0ºC
20.0ºC
3.1ºC
0l/min
0%
Off
Off
CH
Off
Primary flow temp
Hot water temp
Outside temp
Primary water flow
Compressor
CH1 Pump
CH2 Pump
Diverter valve
Immersion heater
08:32
Rotate the dial to highlight functions and change values, press
the dial to select the function and confirm changes
To create a hot water demand select the tap icon in the left
hand column
The following screen will be shown:
25.3ºC
50ºC
Enabled (1 h/week)
Domestic hot water
Hot water temp
Hot water setpoint
Legionella Protect
08:32
STATUS SYMBOLS
Symbol 'Alarm' indicates a plant error.
Symbol 'Maintenance/Special operations' indicates
the presence of a maintenance message or special
operation feedback.
Symbol 'Event' indicates an event message from the
plant.
'Hand' symbol The 'Hand' symbol is displayed if the
plant/zone switch setting is changed by making an
adjustment on the topic pages.
Adjustments made on the topic pages can be reset at
the plant/zone switch.
12:00
The device clock is synchronized with the clock from
the connected controller.
Symbol 'User' and the number to the right (access
level 1 to 3) indicate which user level is currently
active.
• 1: Commissioning engineer
• 2: Heating engineer
• 3: OEM
Symbol 'Producer' indicates the main producer (e.g.
oil/gas boiler, heat pump) that is currently switched
on.
20.0ºC
20.0ºC
3.1ºC
0l/min
0%
Off
Off
CH
Off
Primary flow temp
Hot water temp
Outside temp
Primary water flow
Compressor
CH1 Pump
CH2 Pump
Diverter valve
Immersion heater
1
14:42
• Rotate the dial clockwise for downwards selection
• Rotate the dial anti-clockwise for upwards selection
• Press the dial to make selection
Dial
Screen
20.0ºC
20.0ºC
3.1ºC
10l/min
100%
Off
Off
DHW
Off
Primary flow temp
Hot water temp
Outside temp
Primary water flow
Compressor
CH1 Pump
CH2 Pump
Diverter valve
Immersion heater
08:32
5
1
1
1
1
1