SECTION 2 - INSTALLATION
2.4 INSTALLING THE FLUE
FITTING FLUE THROUGH THE WALL
1.
Ensure the seam and the outlet terminal are at
the top and fitted as shown.
2.
Once the flue is installed it is IMPORTANT that
the white air duct protrudes from the aluminium
flue collar (RSF 060) at least 17mm.
Note. If
less than 50% of the length of the flue is
internal the flue should be fitted from outside.
3.
Fit the internal sealing flubber to the flue (leave
loose) and check protrusion externally of the
white air duct is 17mm.
4.
Fit the turret as below
FITTING THE TURRET -
Ensure the condensate trap / siphon is filled with water
1. Ensure the rubber seal is fitted correctly on the appliance manifold and that all flue seals are undamaged.
2. Hold the flue firmly and push the turret on until it has travelled 30mm on to the flue pipe and is fully engaged. Make sure the
flue has not rotated or moved forward during fitting and the flue seam is upper most.
3. Push the turret into the manifold ensuring the upper plastic lip is flush with the top of the manifold.
4. Fully engage the clamp location section into the manifold location holes. Rotate down on to turret flange.
5. Secure clamp to appliance using securing screw.
6. Ensure all sample points are accessible and all sample plugs and caps are fitted.
7. Fully engage the flue into the turret and slide internal flubber to wall.
8. The gap between the aluminium flue collar (RSF 060) and the white air duct MUST be sealed with sealant to create a seal.
Flue Outlet
C
A
A - Duct Assembly
B - Flue Turret
C - Turret Clamp
D - Seal
Flue Outlet
D
B
Retaining
screw
Clamp Lugs
Sample points
WALL
Aluminium Flue
Collar (RSF 060)
Fill with
sealant
17mm min
Internal Sealing
Flubber
Fill with
sealant
5” hole