SECTION 2 - INSTALLATION
2.2 DETERMINING THE FLUE LENGTH
2.3 CUTTING HORIZONTAL FLUE TERMINAL RSF303 (600MM LONG)
1. Measure from the outer terminal lip to end of outer flue. Mark the
required cut length (A or B + 47mm) around the circumference of the
outer flue and cut following the mark to ensure its cut square.
2. Dress the cut end to make sure all burr’s are removed and the cut
edge is in its original shape.
3. Mark the inner tube 10mm longer than the outer tube around its
circumference and cut following the mark to ensure its cut square.
4. Remove all burrs and place a light chamfer on the outer edge to aid
assembly.
Centre of turret to edge of turret = 100mm
Turret has a flue insertion of 30mm
The white outer flue tube must protrude the wall by 17mm.
From centreline of turret to wall. Rear mount 155mm, side (including clearance) 200mm
NOTES
REAR
Fit
to wall
A
Flue length measured from outer terminal lip
to end of outer flue
A or B
+ 47mm
SIDE
Fit
to wall
B
Minimum clearance 2.5mm
W
ALL
W
ALL
FIGURE 1
10mm
Mark cut length =
A or B + 47mm from terminal lip
REAR FLUE
Cut flue length = distance from edge of turret to outside of
wall dimension A + 47mm.
Note
. Minimum dimension A which can be accommodated is
91mm.
SIDE FLUE
Cut flue length = distance from edge of turret to outside of
wall dimension B + 47mm.
Note
. Minimum dimension B which can be accommodated is
136mm (with minimum clearance of 2.5mm).