4

2 - USE AND SAFETY

PLEASE READ THIS SECTION CAREFULLY BEFORE ATTEMPTING TO HANDLE OR USE THE 

ULTIMATE CONTOUR SYSTEM. IMPROPER USE CAN CAUSE INJURY

2.1 Indications for Use

The Ultimate Contour is intended for

1.  Application of non-thermal radio frequency for relief of minor muscle aches and pains, relief of muscle 

spasm, temporary improvement of local blood circulation, and temporary reduction in the appearance 

of cellulite.

2.  Application of ultrasound for non-invasive reduction in abdominal circumference.

 

 

2.2 Contra-Indications

WARNING: 

The ultrasound handpiece may be audible or create a ringing or buzzing 

sensation in the ears that may be very uncomfortable to the patient. Inform the patient of 

this prior to treatment and for the patient to immediately indicate if this occurs. Reduce the 

intensity setting or discontinue use.

CAUTION: 

Applicator heads may become warm during treatment. To avoid thermal injury 

to the tissue, keep skin wetted with treatment solutions, always keep the handpiece moving 

along the tissue, and use the minimum intensity setting necessary to achieve the desired 

results. 

•  DO NOT

 

use on persons under the age of 18. 

•  DO NOT

 

use ultrasound on persons with a Body Mass Index (BMI) under 25.

•  DO NOT

 use radio therapy on or near the face or neck.

•  DO NOT

 

use on pregnant or nursing women, on those who have given birth in the last 12 months, or 

on those planning to become pregnant.

•  DO NOT

 use near plastic or metal parts within the body (example: implants, stents, ports). Do not allow 

the transducers to contact hard surfaces when activated.

•  DO NOT

 use on patients exhibiting any of the following medical conditions: high blood pressure, heart 

disease or failure, hypertension, hyperlipidemia, diabetes or blood-glucose sensitivity, hepatitis, liver 

disease, abnormal liver or kidney functions, unstable weight changes (> ±3% in the last 6 months), 

HIV positive, blood disorders such as coagulopathy or anemia, aortic aneurysm, connective tissue 

disorders, thyroid disorders, epilepsy, abdominal wall diastasis, hernia, current or previous history of 

cancer or premalignant tissues.

•  DO NOT

 use on patients who have undergone previous body contouring regimens in the last 3 

months, or liposuction in the last 6 months.

•  DO NOT

 use on skin lesions, open wounds, abrasions, acne, rosacea, tattoos, or on patients with a 

tendency to form keloids, have generally poor skin quality, or have had botox or similar filler injections 

near the treatment area within the last month.

•  DO NOT

 use on skin with visible or underlying implanted or foreign bodies (body jewelry, replacement 

Summary of Contents for Ultimate Contour

Page 1: ......

Page 2: ...p 9 4 3 Registration 9 4 4 Handpiece Attachment 9 5 DEVICE OPERATION 10 5 1 Patient Preparation 10 5 2 Screens and Settings 10 5 3 Radio Frequency Treatment 13 5 4 Ultrasound Treatment 14 5 5 Concludi...

Page 3: ...y Failure to read these instructions may result in damage to the device or risk of injury to you or to the patient It is advisable to keep this document with the device and refer to it often when ques...

Page 4: ...s with a Body Mass Index BMI under 25 DO NOT use radio therapy on or near the face or neck DO NOT use on pregnant or nursing women on those who have given birth in the last 12 months or on those plann...

Page 5: ...ls such as antenna cables and external antennas should be used no closer than 30 cm 12 inches to any part of the Ultimate Contour including cables specified by Ideal Curves Otherwise degradation of th...

Page 6: ...onnected to an oxygen supply DO NOT use in the presence of flammable gases All treatments performed with this system must be subjected to the same clinical assessment as with traditional techniques Th...

Page 7: ...e waist circumference of patients using the ultrasound portion This study evaluated a total of 42 individuals who were treated for 30 minutes at an intensity level of 4 during each treatment session T...

Page 8: ...hock ONLY Federal law restricts this device to sale by or on the order of a physician CAUTION Make sure the unit is positioned so you can get easy access to the back panel of the unit in case you need...

Page 9: ...e easily disconnected if needed If needed clean the unit and handpieces as described in Section 6 4 3 Registration Before beginning use of the Ultimate Contour it is highly recommended that you take a...

Page 10: ...istent with the diameter of the handpiece This will help ensure that all of the treatment area is addressed and to help avoid overlapping treatment spots applying excessive energy to a section of tiss...

Page 11: ...rently selected The relative power level of the energy The handpiece that is connected to the unit Details about specific differences will be discussed in Sections 5 3 To change the treatment time or...

Page 12: ...stop the treatment early and then press the Standby button to return to the Standby screen the time will reset to the full amount of time you had selected CAUTION Do not lift up the handpiece during...

Page 13: ...rth sweeping motion A good analogy to think of is mowing a lawn consistent sweeping patterns that just barely overlap slowly working from one side of the area to the other Apply slight pressure into t...

Page 14: ...and the unit has stopped delivering energy lift the handpiece away from the patient tissue Set the handpiece aside Use clean towels to wipe away excess treatment oil from the skin Assess the treated a...

Page 15: ...be treated with a disinfection solution such as a 1 3 glutaraldehyde solution or 0 2 peracetic acid solution The handpiece should be visibly wet and remain so for at least 5 minutes You may need to re...

Page 16: ...th its accessories excluding the handpieces collectively defined as Product is warranted against defective materials and workmanship for a period of one 1 years from the date of purchase If the Produc...

Page 17: ...you are having trouble with the Ultimate Contour system have questions regarding its use or need to order replacement parts feel free to contact a customer service representative at Ideal Curves 1 888...

Page 18: ...ins of a burning sensation Some warmth is normal as this indicates the procedure is working If the heat is intolerable use a lower power setting Also ensure an ample amount of treatment oil is applied...

Page 19: ...0 50 W cm2 1 00 W cm2 Level 3 0 75 W cm2 1 50 W cm2 Level 4 1 05 W cm2 2 00 W cm2 Ultrasound Focal Distance 6mm Ultrasound Focal Distance 6mm Ultrasound Focal Volume 2 12cm3 Ultrasound Entry Power 30...

Page 20: ...to take mitigation measures such as relocating or re orienting the equipment Harmonic emissions IEC 61000 3 2 Not available Voltage Fluctuations Flicker emissions Not available The Ultimate Contour i...

Page 21: ...in watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey...

Page 22: ...ration distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 d 3 5 V1 P d 3 5 E1 P GHz d 7 E1 P 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 1 17 1 17 2 33 10...

Page 23: ...23 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 24: ...Manufactured for Ideal Curves LLC by CAO Group 4628 West Skyhawk Dr West Jordan UT 84084 www ultimate contour com Rev 4 0 Mar 2021 1 888 861 7211...

Reviews: