SECTION 2 - INSTALLATION
2.16 ELECTRICAL CONNECTIONS
Wiring should be 3 core PVC insulated cable, not less than
0.75mm
2
(24 x 0.2mm), and to BS 6500 Table 16. For IE
reference should be made to the current ETCI rules for
electrical installations.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm contact separation in both poles. The means of
isolation must be accessible to the user after installation.
WARNING
. This appliance MUST be earthed.
A mains supply of 230Vac ~ 50 Hz is required.
The fuse rating should be 3A. All external controls and wiring
must be suitable for mains voltage.
Wiring external to the boiler MUST be in accordance with the
current I.E.E. (BS.7671) Wiring Regulations and any local
regulations.
2.17 INSTALLER WIRING - MAINS
The Vogue Max Combi boiler comes pre-fitted with 1.8m of
mains cable. This must be connected to a permanent live supply
and NOT switched by thermostats/programmers. If the supply
cord is damaged, it must be replaced by the manufacturer,
service agent or similarly qualified persons in order to avoid
hazard.
Accessing the installer wiring
1. Isolate the mains supply from the boiler.
2. Remove the front panel. Refer to section 3.2.
3. Swing down the control box into the service position,
remove the retaining screw, and remove the installer
wiring cover.
All of the connections can now be readily accessed, the plugs
can be removed to aid wiring.
Note the cable strain relief system and grommets. Once any
wiring is completed, to secure the boiler, reverse the order
above.
Note 1
The link wire on the 230V installer room stat/timer
connection gives a demand in conjunction with the OpenTherm
link wire (located on the right hand side of the control box).
INSTALLER CONNECTIONS