23
Response 80 / 100 / 120
- Installation
27
MOUNTING THE BOILER
28
CONNECTING THE TURRET TO THE BOILER
3. Drill a 3.2mm hole through the flue via the hole already
present in the turret. Secure the turret to the flue, using
the self tapping screw provided.
1. Mate the turret to the flue.
2. Secure the flue turret on top of the boiler by inserting the
open ends of the turret clamp under the 2 studs and
fixing it in the middle with the single M5 x 10mm pozi-hex
screw provided.
4. Flues over 1 metre long
Fix the flue support bracket
to the wall, using the wall
plug and wood screw.
•
For standard
installations use the
short wood screw.
•
If the 'stand-off' option
is used secure the
support bracket, using
the spacer bracket and
long wood screw.
INSTALLATION
SIDE FLUE OUTLET
1. The boiler may be prewired to the loose
electrical connector and secured with the
cable clamps. Refer to Frame 39.
2. WARNING. Ensure that the plastic plugs are
removed from both the DHW and CH pipes
before mounting.
N.B. Some spillage of water may occur from
the pipework when mounting the boiler to the
frame.
3. Lift the boiler onto the wall mounting frame,
locating it over the tabs at the top of the frame.
4. Lower the boiler into position.
5. Remove the bottom panel to access service
connections.
6. Fit the filter to the DHW inlet valve, as shown.
7. Using the correctly sized fibre washers
supplied in the hardware pack, engage and
then tighten the 4 water unions.
8. Engage and tighten the gas union.
9. Fix the pipe and fibre washer to the safety
drain outlet which is supplied in the boiler
hardware pack.