52
Response 80 / 100 / 120
- Installation
FAULT FINDING
F
AUL
T FINDING
Has overheat
'stat tripped ?
(reset button
under RHS of
boiler)
82
Fan not running
Foot Note:
Presence of live supply on a terminal may be checked with a multimeter set to the appropriate AC range (apply the other probe
of the meter to mains neutral, e.g. on terminal N of the programmer terminal strip).
NO
Can it be reset when the boiler is cold
?
NO
Reset 'stat. Check
temperatures as the
boiler warms up. If the
overheat 'stat trips:
below 90° - replace the
overheat stat.
above 90° - check CH/
HW thermistors and
replace as required.
YES
Replace
overheat
'stat
Check lead to
transformer
Replace transformer
Is there 24-28 V AC between secondary
terminals (red and black leads) of transformer
?
NO
YES
Has secondary fuse F1 on PCB 40 blown ?
NO
Examine fan wiring harness, checking
especially for loose connections or
disconnected wires.
If no fault found, check fan by substitution.
Does replacement fan run OK ?
NO
Leave replacement PCB fitted
but check the fuses on it.
Fit replacement fan.
NO
Refit original fan. Check
PCB 40 by substitution.
Does fan now run ?
YES
Replace fuse. Examine fan harness, checking
especially for short circuits between wires or
terminals.
If no fault found, power up board
without fan
harness connected. Does fuse F1 blow ?
YES
NO
YES
EXIT
YES
YES
Does the fan
run ?
NO
Replace
PCB 40
NO
Is there mains voltage
between primary
terminals (brown and
blue leads) of mains
transformer ? (Expect
230V 50Hz ± 10%)
YES
YES
Has the
mains fuse F2 on PCB 40 blown ?
Is there a supply at PCB 40 at its mains input
connector? (Expect 230V 50 Hz ± 10%)
YES
NO
Reconnect the
harness and fan and
restore power.
Does the fuse blow ?
Check continuity
of the water
pressure switch
and overheat
'stat - replace as
required.
Make sure the boiler mains switch is ON
and the heating switch is on, if required.
Is the 'Mains On' neon lit ?
YES
NO
Check connections and
continuity of EMC filter
NO
YES
Rectify
external fault
Is there mains voltage to the boiler ?
NO
Go to Frame 86
Check pump for shorts
between L/N and L/E.
If no fault found
disconnect the pump
and lead to PCB 41,
renew fuse and
reconnect each item
one by one until the
faulty item is
determined
NO
NO
YES
Check fan by substitution
YES
WARNING. When panels are removed for service, live parts are exposed so caution should be exercised when fault-finding.
YES
Is the system pressure gauge indicating
water pressure below 0.5 bar ?
Summary of Contents for responce 80
Page 1: ......
Page 62: ...62 Response 80 100 120 Installation NOTES...