User’s

3.   SYSTEM WATER PRESSURE

The system pressure gauge (G - see page 3) 

indicates the central heating system pressure. 

If the pressure is seen to fall below the original 

installation pressure of 1-2 bar over a period 

of time and continue to fall then a water leak 

may be indicated. In this event re-pressurise 

the system as shown below.  If unable to do 

so or if the pressure continues to drop a Gas 

Safe Registered Engineer or in IE a Registered Gas Installer (RGII) 

should be consulted.  

THE BOILER WILL NOT OPERATE IF THE PRESSURE HAS 

REDUCED TO LESS THAN 0.3 BAR UNDER THIS CONDITION.

To Top up the system :-

1.  Ensure both 

A

 & 

B

 handles (blue) are in closed position (as 

shown below) 

2.  Remove the plug and cap and retain.
3. 

Connect the filling loop to the Domestic Hot Water (DHW) inlet and 

tighten.  Also ensure that the other end of filling loop is hand tight.

4.  Turn the Domestic Hot Water (DHW) Inlet 

A

 blue handle to 

the horizontal position.

5.  Ensuring no leaks are seen, gradually turn the filling loop   

handle (blue) 

B

 to the horizontal position.

6.  Wait for the pressure gauge to reach 1 to 1.5 bar.  
7.  Once pressure is reached turn valves 

A

 & 

B

 back to the 

closed position.

8.  Disconnect the filling loop, replace cap and plug.  Note there 

can be some water spillage at this point.

EFFICIENT HEATING SYSTEM OPERATION

The boiler is a high efficiency, condensing appliance which will 

automatically adjust its output to match the demand for heat.  

Therefore gas consumption is reduced as the heat demand is 

reduced.

The boiler condenses water from the flue gases when 

operating most efficiently.  To operate your boiler efficiently 

(using less gas) turn the central heating temperature knob 

(B) to the ‘   ‘ position or lower.  In winter periods it may be 

necessary to turn the knob towards the ‘

MAX

’ position to meet 

heating requirements.  This will depend on the house and 

radiators used.
Reducing the room thermostat setting by 1ºC can reduce gas 

consumption by up to 10%.

WEATHER COMPENSATION

When the Weather Compensation option is fitted to the system 

then the central heating temperature knob (B) becomes 

a method of controlling room temperature.  Turn the knob 

clockwise to increase room temperature and anti-clockwise 

to decrease room temperature.  Once the desired setting has 

been achieved, leave the knob in this position and the system 

will automatically achieve the desired room temperature for all 

outside weather conditions.

BOILER FROST PROTECTION

The boiler is fitted with frost protection that operates in all 

modes, provided the power supply to the boiler is always 

turned on.  If the water in the boiler falls below 5ºC, the frost 

protection will activate and run the boiler to avoid freezing.  

The process does not guarantee that all other parts of the 

system will be protected. 
If a system frost thermostat has been installed, the boiler must 
be set in winter mode, ‘ 

 ’, for the system frost protection to 

run.
If no system frost protection is provided and frost is likely 

during a short absence from home it is recommended to leave 

the system heating controls or built in programmer (if fitted) 

switched on and run at a reduced temperature setting. For 

longer periods, the entire system should be drained.

BOILER RESTART

To restart the boiler, when directed in the listed fault codes (see 

section 8) press the restart button (I).  The boiler will repeat its 

ignition sequence.  If the boiler still fails to start consult a Gas 

Safe Registered Engineer or an IE Registered Gas Installer 

(RGII).

MAINS POWER OFF

To remove all power to the boiler the mains power switch must 

be turned off.

Filling Position

Cap

Plug

Filling 

Loop

B

A

Starting Position

Cap

Filling Loop 

Handle (Blue)

Domestic Hot Water 

(DHW) Inlet Valve

Filling 

Loop

B

A

Plug

Summary of Contents for LOGIC CODE COMBI ESP1

Page 1: ...hat have not been clearly authorised by Ideal Boilers For the very latest copy of literature for specification and maintenance practices visit our website www idealboilers com where you can download the relevant information in PDF format For alternative languages in our User Guides please visit our website www idealboilers com April 2019 UIN 222364 A01 USER GUIDE LOGIC CODE COMBI ESP1 26 33 38 ...

Page 2: ...o the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler ELECTRICITY SUPPLY This appliance must be earthed Supply 230 V 50 Hz The fusing should be 3A IMPORTANT NOTES This appliance must not be operated without the casing correctly fitted and forming an adequate seal If the boiler...

Page 3: ...ler fails to light after five attempts the fault code will be displayed refer to Fault Code page OPERATION MODES Winter Conditions Central Heating and Domestic Hot Water required Set the mode knob C to winter The boiler will fire and supply heat to the radiators but will give priority to domestic hot water on demand Summer Conditions Domestic Hot Water only required Set the mode knob C to summer S...

Page 4: ...nob towards the MAX position to meet heating requirements This will depend on the house and radiators used Reducing the room thermostat setting by 1ºC can reduce gas consumption by up to 10 WEATHER COMPENSATION When the Weather Compensation option is fitted to the system then the central heating temperature knob B becomes a method of controlling room temperature Turn the knob clockwise to increase...

Page 5: ... made before it fully defrosts Warm water can also be poured onto the pipe from a watering can or similar DO NOT use boiling water 3 Caution when using warm water as this may freeze and cause other localised hazards 4 Once the blockage is removed and the condensate can flow freely restart the appliance Refer to To Light the boiler 5 If the appliance fails to ignite call your Gas Safe Registered en...

Page 6: ...the time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO HOT WATER OR CENTRAL HEATING Check the mains power is turned on and ensure mode knob C is in the winter position See boiler Operation Modes and Fault Codes section Does the boiler have a display showing o...

Page 7: ...he boiler The boiler is operating in central heating mode The boiler is operating in domestic hot water mode The boiler is operating in frost protection 7 NORMAL OPERATION DISPLAY CODES The boiler mode knob C is in the off position rotate fully clockwise for hot water and central heating operation FP 54 54 00 54 54 o C o C o C o C FOR ANY QUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE 01482 49866...

Page 8: ...arranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII 1 Check condensate pipe for blockages refer to Section 4 2 Check other gas appliances in the house are working to confirm a supply is present in the property 3 If other appliances do not work or there are no other appliances check the gas supply is on at the meter...