background image

3

User’s

 

2.  BOILER OPERATION

continued..........

Legend

A.  Domestic Hot Water Temperature Knob

B.  Central Heating Temperature Knob

C.  Mode Knob

D.  Boiler Status Display

E.  Burner ‘on’ Indicator

F.  Central Heating Economy Setting

G.  Pressure Gauge

H.  Function Button

I.  RESTART Button

ºC

MIN

MAX

MIN

MODE

e

BOILER

OFF

RESTART

MAX

A

G

D H

E I

B

F C

TO START THE BOILER 

If a programmer is fitted  refer to separate instructions for the 

programmer before continuing.
Start the boiler as follows:

1.

  Check that the electricity supply to boiler is off.

2.

  Set the mode knob (C) to ‘

BOILER OFF

’.

3. 

Set the Domestic Hot Water temperature knob (A) and Central 

Heating temperature knob (B) to ‘

MAX

’.

4.

  Ensure that all hot water taps are turned off.

5.

  Switch on electricity to the boiler and check that all external 

controls, e.g. programmer and room thermostat, are on.

6.

  Set the mode knob (C) to ‘ 

 ’ (winter).

The boiler will commence ignition sequence, supplying heat to the 

central heating, if required.

Note. 

In normal operation the boiler status display (D) will show  codes:

00

 

Standby - no demand for heat.

 

Central Heating being supplied

 

Domestic hot water being supplied

FP

 

Boiler frost protection

 

- boiler will fire if temperature is below 5ºC.

During normal operation the burner on indicator ‘ ’ will remain 

illuminated when the burner is lit.

Note:  If the boiler fails to light after five attempts the fault code 

will be displayed (refer to Fault Code page).

OPERATION MODES

Winter Conditions -

 (Central Heating and Domestic Hot Water required)

Set the mode knob (C) to ‘ 

 ’ (winter). 

The boiler will fire and supply heat to the radiators but will give 

priority to domestic hot water on demand.

Summer Conditions - 

(Domestic Hot Water only required)

Set the mode knob (C) to ‘   ’ (summer). 
Set the central heating demand on the external controls to OFF.

Boiler Off

Set the mode knob (C) to ‘

BOILER OFF

’.   The boiler mains 

power supply must be left on to enable frost protection (see Frost 

Protection).

CONTROL OF WATER TEMPERATURE

Domestic Hot Water

The domestic hot water temperature is limited by the boiler 

controls to a maximum temperature of 65

º

C, adjustable via the 

domestic hot water temperature knob (A).
Approximate temperatures for domestic hot water:

Knob Setting

Hot Water Temperature (approx.)

Minimum

40ºC

Maximum

65ºC

Due to system variations and seasonal temperature fluctuations 

domestic hot water flow rates/temperature rise will vary, requiring 

adjustment at the tap : the lower the flow rate the higher the 

temperature, and vice versa.

Central Heating

The boiler controls the central heating radiator temperature to a 

maximum of 80

o

C, adjustable via the central heating temperature 

knob (B).  
Approximate temperatures for central heating:

Knob Setting

Central Heating Radiator Temperature (approx.)

Minimum

30ºC

Maximum

80ºC

For economy setting ‘

’ refer to Efficient Heating System 

Operation.

Summary of Contents for LOGIC CODE COMBI ESP1

Page 1: ...hat have not been clearly authorised by Ideal Boilers For the very latest copy of literature for specification and maintenance practices visit our website www idealboilers com where you can download the relevant information in PDF format For alternative languages in our User Guides please visit our website www idealboilers com April 2019 UIN 222364 A01 USER GUIDE LOGIC CODE COMBI ESP1 26 33 38 ...

Page 2: ...o the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler ELECTRICITY SUPPLY This appliance must be earthed Supply 230 V 50 Hz The fusing should be 3A IMPORTANT NOTES This appliance must not be operated without the casing correctly fitted and forming an adequate seal If the boiler...

Page 3: ...ler fails to light after five attempts the fault code will be displayed refer to Fault Code page OPERATION MODES Winter Conditions Central Heating and Domestic Hot Water required Set the mode knob C to winter The boiler will fire and supply heat to the radiators but will give priority to domestic hot water on demand Summer Conditions Domestic Hot Water only required Set the mode knob C to summer S...

Page 4: ...nob towards the MAX position to meet heating requirements This will depend on the house and radiators used Reducing the room thermostat setting by 1ºC can reduce gas consumption by up to 10 WEATHER COMPENSATION When the Weather Compensation option is fitted to the system then the central heating temperature knob B becomes a method of controlling room temperature Turn the knob clockwise to increase...

Page 5: ... made before it fully defrosts Warm water can also be poured onto the pipe from a watering can or similar DO NOT use boiling water 3 Caution when using warm water as this may freeze and cause other localised hazards 4 Once the blockage is removed and the condensate can flow freely restart the appliance Refer to To Light the boiler 5 If the appliance fails to ignite call your Gas Safe Registered en...

Page 6: ...the time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO HOT WATER OR CENTRAL HEATING Check the mains power is turned on and ensure mode knob C is in the winter position See boiler Operation Modes and Fault Codes section Does the boiler have a display showing o...

Page 7: ...he boiler The boiler is operating in central heating mode The boiler is operating in domestic hot water mode The boiler is operating in frost protection 7 NORMAL OPERATION DISPLAY CODES The boiler mode knob C is in the off position rotate fully clockwise for hot water and central heating operation FP 54 54 00 54 54 o C o C o C o C FOR ANY QUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE 01482 49866...

Page 8: ...arranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII 1 Check condensate pipe for blockages refer to Section 4 2 Check other gas appliances in the house are working to confirm a supply is present in the property 3 If other appliances do not work or there are no other appliances check the gas supply is on at the meter...

Reviews: