Installation & Servicing
INSTALLATION
3
nm8258
1
nm8403
27 CONNECTING THE FLUE TO THE BOILER
1.
Fit the turret seal (supplied in the hardware
pack) to turret, locate the flue into the turret
and push to ensure full engagement. Use
lubricant from hardware pack to lubricate
seals when engaging.
2. CHECK THAT THE FLUE SEAL LOCATED IN
THE TOP OF THE FLUE MANIFOLD IS
SECURE AND GIVING AN EFFECTIVE SEAL.
3.
Secure the flue turret on top of the boiler with
the 4 screws provided.
5. Flues over 1 metre long.
Fix the flue support bracket to the wall, using
the wall plug and screws.
26 MOUNTING THE BOILER
Note.
Refer to Safe Handling (Page 7).
1.
Lift the boiler onto the wall mounting plate, as shown.
2.
Check the boiler alignment using a spirit level and
adjust as necessary with the jacking screw.
nm8167
1
3
2
3.
Fix boiler to wall mounting plate using self
tapping screw (supplied in hardware pack).
4.
Connect condensate hose to the S-trap. Ensure
correct end is used.
INST
ALLA
TION
4