16
INSTALLATION
Classic
Slimline FF
-
Installation & Servicing
REAR FLUE OUTLET
1. Pull the flue through and locate the 3 studs in the
holes in the back panel.
2. Secure the flue to the boiler using the three M5
wing nuts provided.
3. Pull the flue extension tube and engage onto the
fan. Locate and secure with the M4 screw
attached to the fan.
Note.
The sealing ring studs will locate in the back panel
one way only. This will ensure that the terminal grille
is correctly aligned.
1. Lift the boiler onto the wall mounting plate
as shown.
Do not use the burner / controls for lifting
2. Fit an additional No.14 x 50mm woodscrew
through the slot in the boiler back panel
above the flue into the wall plug. Use the
washer and rectangular sealing plate to
seal the slot and retain the boiler.
Note.
Before fully tightening the retaining screw check
the boiler alignment, using a spirit level, and
adjust as necessary with the jacking screw.
19 CONNECTING THE FLUE TO THE BOILER
20 TERMINAL WALL PLATE
This plate allows neat concealment and full compression of
the rubber seal. Its use is not essential if the flue hole and
flue ducts have been accurately cut and the outside wall
face is flat.
1. Position the terminal wall plate over the terminal.
2. Mark and drill 4 fixing holes with an 7mm (
9/32
") masonry
drill.
3. Insert the 4 plastic plugs provided.
4. Secure the plate with 4 of the No.10 x 2" screws
provided.
Note.
If the terminal is less than 2m (6' 6") above ground
level, an approved terminal guard should be fitted. Refer to
the Contents List on Page 3.