SAFETY PRECAUTIONS

READ SAFETY PRECAUTIONS BEFORE INSTALLATION:

Incorrect operation due to ignoring instructions can cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a 

WARNING

 or 

CAUTION.

 WARNING

DO NOT

 attempt to service the unit yourself. This unit has no user 

serviceable components. Opening or removing the cover will expose you 
to dangerous voltage. 

Never put hands or objects into the air outlet of indoor or outdoor units. 
These units are installed with a fan running at high speed. To touch the 
moving fan will cause serious injury.

DO NOT

 attempt to install this unit by yourself. This unit requires 

installation by qualified professionals. 

Ventilate the room regularly while the air conditioner is in use, especially 
if there is also a gas appliance in use in this room, failure to follow these 
directions may result in a loss of oxygen in the room.

To prevent electric shock, turn off the power or disconnect the power 
supply before beginning any cleaning or other routine maintenance. 
Follow the directions for cleaning in the user manual.

DO NOT

 use liquid cleaners or aerosol cleaners, use a soft and dry cloth 

for cleaning the unit. To avoid electric shock, never attempt to clean the 
units by spraying with water.

DO NOT

 use caustic household drain cleaners in the unit. Drain cleaners can 

quickly destroy the unit components (drain pan and heat exchanger coil etc).

This symbol indicates that ignoring 
instructions may cause damage to 
your unit, or other property, serious 
injury or death.

This symbol indicates that ignoring 
instructions may cause moderate 
injury to you, or damage to your 
unit or other property.

WARNING

CAUTION

Danger

No

Thinner

No

Household

Drain

Cleaner

NOTE:

For proper performance, operate the unit in temperature and humidity 

ranges indicated in this owner's manual. If the unit is operated beyond 

these conditions, it may cause malfunctions of the unit or dew dripping 

from the unit.

CAUTION

Summary of Contents for 700026

Page 1: ...r conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner Before operating this product please read the instructions carefully and save this manual for future use 700026 700027 700028 700029 PRO DUAL MINI SPLIT I N D O O R C E I L I N G M O U N T ...

Page 2: ...ersonal safety hazard on your purchase of Ideal Air s Pro Dual Mini Split indoor unit We re proud to offer this product and believe it s the very best in its class 2 SAFETY PRECAUTIONS 3 MANUAL OPERATION 5 ADJUSTING AIR FLOW DIRECTION 5 MAINTENANCE 6 AIR CONDITIONER OPERATIONS AND PERFORMANCE 8 INSTALLATION 9 TROUBLES AND CAUSES 9 TROUBLES AND CAUSES CONCERNING REMOTE CONTROL 10 MATCH UP CHART 11 ...

Page 3: ...oss of oxygen in the room To prevent electric shock turn off the power or disconnect the power supply before beginning any cleaning or other routine maintenance Follow the directions for cleaning in the user manual DO NOT use liquid cleaners or aerosol cleaners use a soft and dry cloth for cleaning the unit To avoid electric shock never attempt to clean the units by spraying with water DO NOT use ...

Page 4: ...only FUNC Indoor Unit Air outlet Drain hose Drain Pump Internal installed water drain from indoor unit Infrared Signal receiver Timer indicator Alarm indicator Defrost indicator heating cooling type or fan indicator cooling only type Outdoor Unit Vertical louver Manual button SET button Remote Control Connecting pipe Run lamp 1 7 10 4 9 13 15 2 3 11 12 14 8 5 6 Air Inlet Air filter installed insid...

Page 5: ...ll control box of the indoor unit Once you push this button the air conditioner will run in such order AUTO MANDATORY COOL OFF and back to AUTO AUTO The OPERATION lamp is lit and the air conditioner will run under AUTO mode The remote control operation is enabled to operate according to the received signal MANDATORY COOL The OPERATION lamp flashes the air conditioner will turn to AUTO after it is ...

Page 6: ...tom of the room Please set the louver so that the air can come out downwards WARNING CAUTION If you do not plan to use the unit for at least 1 month Operate the fan for about half a day to dry the inside of the unit Stop the air conditioner and disconnect power Remove the batteries from the remote control Before you clean the air conditioner be sure to disconnect the power supply CHECKS BEFORE OPE...

Page 7: ...E 1 Open the air in grill Push the grill switches towards the middle simultaneously as indicated in sketch A Then pull down the air in grill A B CEILING TYPE 1 Open the air in grill Push the grill switches towards the middle simultaneously as indicated in following figure sketch Then pull down the air in grill The control box cables which are originally connected with the main body electrical term...

Page 8: ...he power and then connect the unit with the power again Push the ON OFF button on the remote control to restart operation AIR CONDITIONER OPERATING CONDITIONS For proper performance run the air conditioner under the following temperature conditions Mode Cooling operation Heating operation Drying operation Temperature 1 If air conditioner is used outside of the above conditions certain safety prote...

Page 9: ...uch substances may lead to failure of the air conditioner BE CAREFUL OF NOISE OR VIBRATIONS Please install the unit in a stable place to avoid noise or vibrations Locate the outdoor unit where noise emitted by it or hot air from its air outlet will not cause nuisance to your neighbors If the air conditioner sounds abnormal during operation contact the service professional that installed your unit ...

Page 10: ...ay disappears after a lapse of time The ON TIMER indicators go off after a lapse of certain time Check whether the timer operation has come to an end when the OFF TIMER is indicated on the display Check whether the timer operation is started when the ON TIMER is indicated on the display The air conditioner operation stops since the set time elapsed When the time set to start the air conditioner is...

Page 11: ...munication checking channel is abnormal T2b sensor error Outdoor EEPROM error Outdoor fan speed malfunction Only for DC fan motor Discharging air temperature sensor error Outdoor condenser pipe temperature sensor error E0 E1 E3 E4 E5 EC EE E8 E9 F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 P0 P1 P2 P3 P4 P5 ON ON ON ON ON ON ON ON ON ON Flash Flash Flash Flash Flash Flash High temperature protection of compresso...

Page 12: ... answers to most common questions and a complete technical support library please visit www ideal air com All design and specifications herein are subject to change without notice for product improvement Contact Ideal AirTM for details updates and other information DO NOT return this product to the store where you purchased it ...