Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...4 ...

Page 5: ... screw for remote controller holder ST2 9 x 10 Remote controller holder Dry battery AAA LR03 Seal Drain joint Mounting plate 5 5 2 1 Optional Parts 2 1 1 User manual Installation manual Line sets sold separately Connecting pipe assembly Liquid side Gas side 6 35 1 4 9 52 3 8 9 52 3 8 12 7 1 2 16 5 8 ...

Page 6: ...nstallation Location Page 9 And Drill Wall Hole Page 10 1 Attach Mounting Plate Page 10 2 Prepare Refrigerant Piping Page 12 4 3b 12cm 4 75 2 3m 90 55 12cm 4 75 15cm 5 9 Determine Wall Hole Position Page 10 3a ...

Page 7: ...Mount Indoor Unit Page 16 STEP 8 Wrap Piping and Cable Page 15 1 2 3 Connect Drain Hose Page 13 Connect Signal Cable Page 14 5 6 7 8 ...

Page 8: ...l Mounting Plate Refrigerant Piping Signal Cable Drainage Pipe Louver Functional Filter On Front of Main Filter Some Units Front Panel Outdoor Power Cable Some Units Remote Holder Remote Control Some Units ...

Page 9: ......

Page 10: ...12cm 4 75 or more 2 3m 90 55 or more 12cm 4 75 or more 15cm 5 9 or more Wall Indoor Outdoor m m 7 5 0 2 0 3 ...

Page 11: ...2 55 57mm 2 25 40mm 1 55 Right rear wall hole 65mm 2 5 Model C 965mm 38 138mm 5 45 34mm 1 35 517 4mm 20 37 Indoor unit outline Left rear wall hole 65mm 2 5 219mm 8 6 553mm 21 77 300mm 11 8in 335mm 13 2 Right rear wall hole 65mm 2 5 Model D 1080mm 42 5 53 5mm 2 1 47mm 1 85 76mm 3 53 5mm 2 1 47mm 1 85 148 7mm 5 85 151mm 5 95 174 3mm 6 85 Indoor unit outline Left rear wall hole 65mm 2 5 172mm 6 8 362...

Page 12: ...Knock out Panel ...

Page 13: ...re proper drainage NOT CORRECT Kinks in the drain hose will create water traps NOT CORRECT Kinks in the drain hose will create water traps NOT CORRECT Do not place the end of the drain hose in water or in containers that collect water This will prevent proper drainage ...

Page 14: ...iance Amps A AWG 10 18 13 16 18 14 25 12 30 10 Other Regions Rated Current of Appliance A Nominal Cross Sectional Area mm in2 3 and 6 0 75 03 6 and 10 1 28 10 and 16 1 5 06 16 and 25 2 5 10 25 and 32 4 16 32 and 40 6 24 ...

Page 15: ...minal block Wire cover Screw Cable clamp The Wiring Diagram is located on the inside of the indoor unit s wire cover Indoor Unit Space behind unit Refrigerant piping Drain hose Signal wire Insulation tape ...

Page 16: ...Move to left or right 30 50mm 1 2 1 95 30 50mm 1 2 1 95 ...

Page 17: ...e v o b a 24 m c 0 6 60cm 24 on right 30cm 12 on left 200cm 79 in front 30cm 12 from back wall Strong wind Strong wind Strong wind Wind baffle ...

Page 18: ...x700x320 33 25 x27 5 x12 6 560 22 335 13 2 810x558x310 31 9 x22 x12 2 549 21 6 325 12 8 900x860x315 35 4 x33 85 x12 4 590 23 2 333 13 1 945x810x395 37 2 x31 9 x15 55 640 25 2 405 15 95 946x810x420 37 21 x31 9 x16 53 673 26 5 403 15 87 946x810x410 37 21 x31 9 x16 14 673 26 5 403 15 87 845x702x363 33 25 x27 63 x14 29 540 21 26 350 13 8 700x550x275 27 5 x21 6 x10 82 450 17 7 260 10 24 770x555x300 30 ...

Page 19: ......

Page 20: ...ther Regions Rated Current of Appliance A Nominal Cross Sectional Area mm in2 3 and 6 0 75 03 6 and 10 1 04 10 and 16 1 5 06 16 and 25 2 5 10 25 and 32 4 16 32 and 40 6 24 Cover Outdoor Unit Wiring Diagram is located on the inside of the wire cover on the outdoor unit ...

Page 21: ...odel Capacity BTU h Max Length m Max Drop Height m R410A Inverter Split Air Conditioner 15 000 25 82 10 33 15 000 and 24 000 30 98 5 20 66 24 000 and 36 000 50 164 25 82 36 000 and 60 000 65 213 30 98 5 ...

Page 22: ... 10cm 4 Radius Outer Diameter of Pipe mm A mm Min Max Ø 6 35 Ø 0 25 0 7 0 0275 1 3 0 05 Ø 9 52 Ø 0 375 1 0 0 04 1 6 0 063 Ø 12 7 Ø 0 5 1 0 0 04 1 8 0 07 Ø 16 Ø 0 63 2 0 0 078 2 2 0 086 ...

Page 23: ...m Tightening Torque N cm Add Tightening Torque N m Ø 6 35 Ø 0 25 1 500 11lb ft 1 600 11 8lb ft Ø 9 52 Ø 0 375 2 500 18 4lb ft 2 600 19 18lb ft Ø 12 7 Ø 0 5 3 500 25 8lb ft 3 600 26 55lb ft Ø 16 Ø 0 63 4 500 33 19lb ft 4 700 34 67lb ft Valve cover ...

Page 24: ...Inverter R410A Fixed frequency R410A Inverter R410A Fixed frequency R410A Pipe length standard length x 15g m Pipe length standard length x 0 16oZ ft Pipe length standard length x 20g m Pipe length standard length x 0 21oZ ft Pipe length standard length x 40g m Pipe length standard length x 0 42oZ ft Liquid Side Ø 9 52 ø 0 375 R22 Pipe length standard length x 60g m Pipe length standard length x 0...

Page 25: ...Indoor and outdoor units are solidly installed All pipe connection points do not leak Outdoor 2 Indoor 2 Water drains properly from drain hose All piping is properly insulated Unit performs COOL function properly Unit performs HEAT function properly Indoor unit louvers rotate properly Indoor unit responds to remote controller ...

Page 26: ...Manual control button ...

Page 27: ......

Page 28: ......