POWER ON/OFF SWITCH
If the equipment has a Power switch, the Power switch used in this piece of equipment DOES NOT break the connection from
the mains.
MAINS DISCONNECT
The plug shall remain readily operable.
For rack mount or installation where plug is not accessible, an all-pole mains switch with a contact separation of at least 3
mm in each pole shall be incorporated into the electrical installation of the rack or building.
FOR PRODUCTS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE RECEPTACLE
Replace fuse with same type and rating only.
MULTIPLE-INPUT VOLTAGE
This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power
source at installation.
Connect this equipment only to the power source indicated on the equipment rear panel.
To reduce the risk of fire or electric shock, refer servicing to qualified service personnel or equivalent.
If connected to 240V supply, a suitable CSA/UL certified power cord shall be used for this supply.
This equipment is intended for rack mount use only.
THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE EARTHING CONNECTION.
The cores in the mains lead are colored in accordance with the following code:
GREEN and YELLOW - Earth
BLUE - Neutral
BROWN - Live
As colors of the cores in the mains lead of this appliance may not correspond with the colored markings identifying the
terminals in your plug, proceed as follows: The core which is colored green and yellow must be connected to the terminal in
the plug marked with the letter E, or with the earth symbol, or colored green, or green and yellow.
The blue core must be connected to the terminal marked N or colored black.
The brown core must be connected to the terminal marked L or colored red.
This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power
source at installation.
If the attachment plug needs to be changed, refer servicing to qualified service personnel who should refer to the table below.
The green/yellow wire shall be connected directly to the processor’s chassis.
WARNING
: If the ground is defeated, certain fault conditions in the processor or in the system to which it is connected can
result in full line voltage between chassis and earth ground.
Severe injury or death can then result if the chassis and earth ground are touched simultaneously.