12000 Ford Road, Suite 110, Dallas, TX 75234
Tel: 972-247-1203
Fax: 972-247-1291
www.idview.com
7 / 25
from down to up
Rules: can be set to forbid bi-directional, enter, leave, 3 directions, when the moving objects meet the picket area rules,
alarm will be activated
Step 1: [Main Menu]> [Alarm]> [Intelligent Video analysis], enter video analysis setting interface, enable this function.
Step 2: click rule to enter the rule setting interface, see pic 8:
Pic 8 Rule setting
Step 3: enable show track function, adjust level of sensibility and minimum image distance. Set picket mode, choose picket
line or picket area, click setting to enter the “Config” interface, right click the mouse and choose add, use mouse to set two
or more points then connect to form a line or a irregular area, after that will come out an option box of forbidden direction,
choose one of them and right click mouse, then click yes return to pre-interface, click yes to finally finish alarm rules
setting.
Step 4: setting steps of alarm control period and the taken linkage measures is the same as step 2 and step 3 in alarm setting
10.1
Step 5: when video analyze alarm happens, there will be red box line in the preview image.
The intelligent analyze function mainly including below 4 facets:
1. Perimeter detection
(
PEA
)
(1). touch line detection: bi-directional touch line, single-direction touch line
(2). Area detection: enter alarm, leave alarm