___________________________________________________________________
Co
Brite
DX1
User Manual
26
5.5.7
Import Laser configuration
This button will open a File dialog that allows loading a configuration in to the set
table. This can be either a file that was saved previously or a configuration generated
by the user. Press the according set buttons or use the “Set all” button to activate the
configuration.
The file format is ASCII csv based:
Example:
Chassis#,Slot#,Laser#,Frequency,FTF,Power,State,SBS,Dither
1,1,1,191.4,0,5.99,1,1,1
1,1,2,191.5,0,5.99,1,1,1
1,1,3,191.5998,0,6,1,1,1
1,1,4,191.6999,0,5.99,1,1,1
1,2,1,191.8079,0,5.96,1,1,1
1,2,2,191.905,0,6.01,1,1,1
1,2,3,192.2754,0,5.99,1,1,1
1,2,4,192.1069,0,6,1,1,1
5.5.8
Set selected
This button will configure the current parameters in the set table to all laser ports that
were selected using the corresponding check box.
5.5.9
None/All
This button will select or deselect the checkboxes of all available laser ports.
5.5.10
Wavelength/Frequency button
This button allows entering the Laser Frequency in either frequency or wavelength
format. Current values in the set table will automatically be converted.
5.5.11
Disable Temperature Info
This button will enable or disable the reading of temperature and laser current
information from all lasers. This is useful for systems with a high port count
increasing the refresh rate of the information read from the lasers.
5.5.12
Max. Base Temperature
The maximum laser housing temperature of all lasers is displayed including location
identifier of this laser. This value is displayed for information only as all lasers are
temperature compensated and will operate within specification for specified ambient
temperatures if air flow to the chassis is not blocked. Note that Lasers will be
switched off if the base temperature exceeds 60°C to prevent hardware damage.
Summary of Contents for CoBrite Series