AC Power Supply
The power supply should be supplied by a dedicated electrical power source rated for a minimum 10A load and
have a dedicated circuit breaker.
Do not
use a switch controlled breaker or a switched electrical point to supply
electrical power. Connect the primary of a 16 to 16.5 VAC, 50-60Hz, 40VA or greater transformer to the
electrical circuit and run the secondary to the AC input on the power supply terminals.
AC Power Connection
Transformer
Mains Input
AC
AC
B+
B-
Specific regional regulations may allow the transformer to be mounted inside the cabinet enclosure. In this case
wire the electrical circuit to the electrical termination point inside the cabinet enclosure and the secondary wires
of the transformer to the AC input on the power supply. The earth wire shall be routed to the V- terminal on the
power supply when using an internal transformer.
Warning:
⦁
This installation should be made by qualified service personnel and should conform to all local codes.
⦁
Termination of wiring to the power supply while power is applied or the battery is connected may cause
serious damage to the power supply and will
VOID ALL WARRANTIES OR GUARANTEES
. Power the unit
only after all wiring, configuration and jumper settings are completed.
⦁
Extra care must be taken when wiring the AC inputs. Improper connection will cause permanent damage
to the power supply.