Vibration Sensor
Protection is provided by a DSC SS-102 Shockgard seismic vibration sensor mounted within the system
enclosure.
Connection
⦁
Terminals
1(V+) and 2(V-)
.
12V power connection
, reverse polarity protected.
⦁
Terminals
3 and 4
. N.C.
alarm output contacts
, with built in 10 ohm resistor in series.
1.
12V (Screw terminal 1).
2.
0V (Screw terminal 2).
3.
Alarm circuit. N/C contact. (Screw terminals 3&4).
PRT-PSU-DIN-2A | Protege DIN Rail 2A Intelligent Power Supply | Installation Manual