Technical Specifications
The following specifications are important and vital to the correct operation of the Reader Expander. Failure to
adhere to the specifications will result in any warranty or guarantee that was provided becoming null and void.
Integrated Control Technology continually strives to increase the performance of its products. As a result these
specifications may change without notice. We recommend consulting the ICT website (http://www.ict.co) for the
latest documentation and product information.
Power Supply
DC Input Voltage
12VDC (+/-10%)
R1/R2 DC Output Voltage
12VDC 700mA (Typical) Electronic Shutdown at 1.1A
Operating Current
40mA (Typical) 110mA (Max, All Relays Activated)
Low Voltage Cut-out
8.7VDC
Low Voltage Restore
10.5VDC
Communication
RS-485
Isolated Module Network
Outputs
Lock Outputs
2 FORM C Relay Outputs, 7A 250V Max
PGM Outputs
6 (50mA Max) Open Collector
Inputs
Zone
8 (10ms to 1hr Input Speed Programmable)
Tamper
Dedicated Hardware Tamper Input
Trouble Zone
16
Dimensions
PCB Dimensions
96mm X 217mm (3.78" X 8.54")
Weight
156g (5.50oz)
Temperature
Operating
5˚- 55˚ Celsius (41˚ - 131˚ Fahrenheit)
Storage
-10˚- 85˚ Celsius (14˚ - 185˚ Fahrenheit)
Humidity
0%-85% (Non-Condensing)
i
It is important that the unit is installed in a dry cool location that is not affected by humidity. Do not
locate the unit in air conditioning or a boiler room that can exceed the temperature or humidity
specifications.