10
PRT-RDM2-PCB
Protege Mini 2 Reader Expander
Installation Manual | March 2015
3.3
Magnetic Reader Connection
The Reader Expander allows the connection of standard magnetic track 2 format cards and provision is made in
the software for a large number of formats. Formats include BIN number for ATM access control and first 4, 5
and 6 card numbers.
YELLOW
GREEN
RED
BROWN
ORANGE
OUT COM
IN
5v REGULATOR
50mA MAX OUTPUT
+5V
+12V
0V
0V
+ -
DO
L2
D1
L1
BZ
R1
R1
R1
R1
R1
R1
R1
Magnetic Card Reader Interface
i
Magnetic card readers are typically operated by 5 volts. Before connecting the magnetic card reader
to the Reader Expander, ensure that the supply voltage is correct and if required insert the inline 5 Volt
regulator as shown in the diagram above.
3.4
Door Contact Connection
The Reader Expander allows the connection of up to 4 contacts for monitoring and controlling access control
doors. Each zone on the Reader Expander can be used for the door function that is automatically assigned and
as a normal zone input on the system. The following example shows the connection of a normally closed door
position monitoring contact to monitor the open, closed, forced and alarm conditions of the door.
Z1
DOOR1
Z2
Z3
Z4
COM
REX1
SENSE1
REN1
DOOR CONTACT
NORMALLY CLOSED
REQUEST TO EXIT
NORMALLY OPEN
Standard Door Contact Inputs
i
When connected the REX input can be programmed to operate regardless of the door contact state.
The REX input can also be programmed to recycle the door alarm time to prevent nuisance alarms
when the door is held open to permit longer entry.