3.5
Door Lock Connection
The Reader Expander provides two lock output relays that can be used to switch electric locks.
+
-
1N4007 Diode
12VDC Electric
Locking Device
+
-
Power Supply for
Locking Devices
Max 30VDC
NO
CO
M
N
C
Contact Rating 7A,
30VDC or 30VAC
Door Lock Outputs
i
When using a door with an entry and exit reader, the LOCK output should be connected to LOCK
1, and enable the swap lock option for the second reader input to allow the reader LED's to
display the correct status.
The 1N4007 diode shown in the above diagram is supplied with the Reader Expander and MUST
be installed at the electric strike terminals.