background image

 
 

PRT-R

D

M2-PCB

 

Protege Mini 2 Reader Expander 

Installation Manual 
 

Summary of Contents for Protege PRT-RDM2-PCB

Page 1: ...PRT RDM2 PCB Protege Mini 2 Reader Expander Installation Manual...

Page 2: ...produced photocopied or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and ma...

Page 3: ...0 3 5 Door Lock Connection 11 4 Zone Inputs______________________________________________________________ 12 4 1 Zone Inputs 12 4 2 Trouble Zone Inputs 13 5 Programmable Outputs ______________________...

Page 4: ...tralia ________________________________________________ 20 11 European CE and EN 50131 _______________________________________________ 21 12 Ordering Information ______________________________________...

Page 5: ...distance of up to 900M 3000ft Further span can be achieved with the use of a network repeater module Locking a network prevents the removal substitution or addition of modules to the module network ef...

Page 6: ...oles for the keyhole points in the top left and right locations This will allow you to screw in the screws and then hang the box on them adjusting the location to suit 3 Ensure a solid fixing point an...

Page 7: ...ttery backed power supply unit such as the PRT PSU DIN or a networked module capable of supplying the required voltage to all devices on the RS485 network Warning The 12V N and N Communication input m...

Page 8: ...ing an access door and entry exit door DO L2 D1 L1 BZ RED BLACK GREEN WHITE ORANGE BROWN BLUE YELLOW SHIELD R1 R1 R1 R1 R1 R1 R1 Standard Reader Connection Warning The shield connection on the card re...

Page 9: ...DATA 1 input RED BLACK GREEN WHITE ORANGE BROWN BLUE YELLOW SHIELD RED BLACK GREEN WHITE ORANGE BROWN BLUE YELLOW SHIELD Entry Reader Exit Reader Data DO L2 D1 L1 BZ R1 R1 R1 R1 R1 R1 R1 DO L2 D1 L1 B...

Page 10: ...d insert the inline 5 Volt regulator as shown in the diagram above 3 4 Door Contact Connection The Reader Expander allows the connection of up to 4 contacts for monitoring and controlling access contr...

Page 11: ...Supply for Locking Devices Max 30VDC NO COM NC Contact Rating 7A 30VDC or 30VAC Door Lock Outputs i When using a door with an entry and exit reader the LOCK output should be connected to LOCK 1 and en...

Page 12: ...When using a zone with the EOL resistor configuration the controller generates an alarm condition when the state of a zone changes between open and closed and generates a tamper alarm condition when...

Page 13: ...m Tamper System RDxxx 02 AC Failure Power Fault General RDxxx 03 Reserved None None RDxxx 04 Aux Failure Power Fault General RDxxx 05 Reserved None None RDxxx 06 Door 1 Forced Forced Door Access RDxxx...

Page 14: ...7 Diode 12VDC Electric Locking Device Power Supply for Locking Devices Max 30VDC NO COM NC Contact Rating 7A 30VDC or 30VAC Lock Output PGM1 2 Connection 5 2 Standard PGM Outputs 3 To 8 The PGM output...

Page 15: ...ted ONLY if the reader expander is operating offline and the mode of offline operation prevents this card from being allowed access 1 Long Beep 1 Short Beep Access Denied Card Number Not Known The car...

Page 16: ...eader Expander will automatically default the internal configuration and require a network update See the Protege System Reference Manual for information on performing a module update 1 ADDRESS 1 2 AD...

Page 17: ...a non standard mode When the Fault indicator is FLASHING the Reader Expander is operating in boot mode awaiting firmware update When the Fault indicator is ON the Reader Expander is in error state an...

Page 18: ...xpander is not compatible with the system controller To clear this error update the module using the module update application 3 Address Too High The Reader Expander address is above the maximum numbe...

Page 19: ...Output Voltage 12VDC 700mA Typical Electronic Shutdown at 1 1A Operating Current 40mA Typical 110mA Max All Relays Activated Low Voltage Cut out 8 7VDC Low Voltage Restore 10 5VDC Communication RS 48...

Page 20: ...New Zealand and Australia The C Tick compliance label indicates that the supplier of the device asserts that it complies with all applicable standards The SCN establishes a traceable link between a de...

Page 21: ...50131 1 the following points should be noted Ensure for Grade 3 compliant systems the minimum PIN length is set for 6 digits To comply with EN 50131 1 Engineer access must first be authorised by a use...

Page 22: ...should not be programmed to more than 45 seconds To comply with EN 50131 1 the Bell Cut Off Time should be programmed between 02 and 15 minutes EN 50131 1 requires that detector activation LEDs shall...

Page 23: ...following product codes when placing an order for the Protege Mini 2 Reader Expander PRT RDM2 PCB To order the Reader Expander in a cabinet order the CAB MED steel cabinet complete with transformer a...

Page 24: ...the products and because the products may be used in conjunction with products not manufactured by ICT ICT cannot guarantee the performance of the security system ICT s obligation and liability under...

Page 25: ...information below Integrated Control Technology P O Box 302 340 North Harbour Post Centre Auckland New Zealand 11 Canaveral Drive Albany North Shore City 0632 Auckland New Zealand Phone 64 9 476 7124...

Page 26: ...echnology Ltd nor its employees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the Integ...