Protege DIN Rail 8 PGM Output Expander
| Installation Manual
19
12
Technical Specifications
The following specifications are important and vital to the correct operation of the Output Expander. Failure to
adhere to the specifications will result in any warranty or guarantee that was provided becoming null and void.
Power Supply
DC Input Voltage
11-14VDC
DC Output Voltage
(DC IN Pass-Through)
10.83-14.0VDC 0.7A (Typical) Electronic Shutdown at 1.1A
Operating Current
80mA (Typical)
Total Combined Current*
3.25A (Max)
Low Voltage Cutout
8.7VDC
Low Voltage Restore
10.5VDC
Communication
RS-485
Module Network
Outputs
PGM Outputs
8 FORM C Relays, 7A 250V Max
Dimensions
Dimensions (L x W x H)
156.8 x 90 x 60mm (6.17 x 3.54 x 2.36")
Weight
482g (17oz)
Temperature
Operating
0˚-50˚C (32˚ - 122˚F)
Storage
-10˚- 85˚C (14˚ - 185˚F)
Humidity
0%-93% non-condensing, indoor use only (relative humidity)
* The Total Combined Current refers to the current that will be drawn from the external power supply to supply
the Output Expander
and
any devices connected to the Expander's outputs. The Auxiliary outputs are directly
connected via electronic fuses to the N+ N- input terminals, and the maximum current is governed by the trip
level of these fuses.
It is important that the unit is installed in a dry cool location that is not affected by humidity. Do not locate the
unit in air conditioning or a boiler room that can exceed the temperature or humidity specifications.
Integrated Control Technology continually strives to increase the performance of its products. As a result these
specifications may change without notice. We recommend consulting our website (http://www.ict.co) for the
latest documentation and product information.