Power Supply
DC Input Voltage
11-14VDC
DC Output Voltage
(DC IN Pass Through)
10.83-14.0VDC 0.7A (Typical) Electronic Shutdown at 1.1A
Reader 1&2 10.45-13.85VDC Pass Through share 0.7A (Typical) Electronic
Shutdown at 1.1A
Operating Current
80mA (Normal Standby)
Total Combined Current*
1.6A (Max)
Low Voltage Cutout
8.7VDC
Low Voltage Restore
10.5VDC
Communication
RS-485
Module network
Offline Operation
Offline Access Modes
All Users, First 10 Users plus 150 Card Cache, No Users
Readers
Reader Configurations
2 reader ports that can be independently configured for either Wiegand (up to
1024 bits configurable) or RS-485, allowing connection of up to 4 readers
providing entry/exit control for two doors **
RS-485 reader port connections support configuration for OSDP protocol
Outputs
Lock Outputs
2 Form C Relay Outputs - 7A N.O/N.C. at 30 VAC/DC resistive/inductive
Outputs
6 (50mA Max) Open Collector
Inputs
Inputs
8 High Security Monitored Inputs (10ms to 1hr Input Speed Programmable)
Trouble Inputs
16
Dimensions
Dimensions (L x W x H)
78 x 90 x 60mm (3.07 x 3.54 x 2.36")
Net Weight
210g (7.4oz)
Gross Weight
270g (9.5oz)
Operating Conditions
Operating Temperature
UL/ULC 0° to 49°C (32° to 120°F) : EU EN -10° to 55°C (14° to 131°F)
Storage Temperature
-10˚ to 85˚C (14˚ to 185˚F)
PRT-HRDM-DIN | Protege Half DIN Rail 2 Door Reader Expander | Installation Manual