ICT LIMITED WARRANTY  

 
ICT Limited Warranty is only intended for the benefit of the original Purchaser of 
this  product.  This  Warranty  is  not  transferable  or  assignable  without  the  prior 
written permission of ICT. 

ICT’s sole obligation and liability under this warranty is 

limited  to  either repairing or replacing defective products at the sole discretion 
of ICT. When repairing or replacing the products, ICT may use products or parts 
that  are  new,  equivalent  to  new  or  re-conditioned.  Parts  repaired  or  replaced 
during  the  warranty  period  will  be  under  warranty  for  the  remainder  of  the 
warranty period. 
 
The warranty period on ICT products purchased new from ICT is two years.  The 
warranty period for a repaired product or part thereof is ninety (90) days or the 
remainder of the unexpired term of the new product warranty period, whichever 
is greater. Repair or replacement of a defective product or part does not extend 
the original warranty coverage period.  
 
No claim will be accepted unless written notice of the claim is received by ICT in 
accordance  with 

ICT’

s  Return  Material  Authorization  (RMA)  procedure,  as  soon 

as  reasonably  possible  after  the  defect  is  discovered.  A  valid  product  serial 
number must be provided with the RMA claim to prove eligibility. The RMA form 
is available on the ICT website at 

www.ict-power.com/support/warranty-repair/

The  Purchaser  shall  at  their  own  risk  and  cost  return  the  defective  product  to 

ICT’s factory or designated repair center once an RMA is issued by ICT. Return of 

the  products  to  the  customer  after  repair  is  completed  shall  be  prepaid  by  ICT 
unless otherwise mutually agreed between the parties.  Products shipped to ICT 
which have incurred freight damage will not be covered by this Warranty and any 
repairs or replacement parts, components or products needed will be invoiced in 
the full current price amount and returned freight collect to Purchaser.  It is the 

Purchaser’s  responsibility  to  check  the  product  upon  receipt  for  any  damage 

during  shipping  and  to  contact  the  carrier  or  shipper  regarding  such  damage. 
Product  that  is  returned  as  defective,  which  is  determined  to  operate  within 
published specifications will be returned to the Purchaser freight collect.  
 
Warranty  commences  on  the  date  the  product  is  shipped  from  the  ICT 
manufacturing  facility,  or  in  the  case  of  purchase  through  an  authorized  ICT 
reseller, not more than ninety (90) days after original shipment of this product by 
ICT.  
 
ICT  assigns  to  Purchaser  any  warranties  which  are  made  by  manufacturers  and 
suppliers  of  components  of,  or  accessories  for,  the  ICT  product  and  which  are 
assignable.  ICT  makes  no  representations  as  to  the  effectiveness  or  extent  of 
such  warranties,  assumes  no  responsibility  for  any  matters  which  may  be 

All manuals and user guides at all-guides.com

Summary of Contents for ICT24012-15BC2

Page 1: ...00 Innovative Circuit Technology Ltd Models ICT24012 30BC2 ICT24012 30BC2M ICT24012 15BC2 ICT24012 15BC2M ICT24024 15BC2 ICT24024 15BC2M ICT24024 7BC2 ICT24024 7BC2M ICT24048 7BC2 ICT24048 7BC2M All m...

Page 2: ...uit breaker Ensure battery polarity is correct before connecting Do not attempt to charge a frozen battery Handle batteries with care do not short circuit battery terminals CAUTION Risk of personal in...

Page 3: ...charge rates to accommodate lower capacity batteries Wide range Power Factor corrected AC input supports operation world wide Floating Form C alarm contact output supports remote monitoring of unit o...

Page 4: ...LVD relay switches the BATT terminal Do not connect the battery to any other terminal AC input wiring to the charger must be protected using an outlet with a branch rated circuit breaker of 20A or low...

Page 5: ...urrent limit set by the BATT Switch settings 3 4 Use this setting if the connected load requires a non varying output voltage or if the backup battery is not used or if it does not need to be fast cha...

Page 6: ...arm output common Alarm Output Contacts Connect the optional remote battery temperature sensor ICT TMP to the TEMP input on the back panel removable connector Using the TMP sensor will enable the unit...

Page 7: ...l bypass critical internal circuitry disabling the charge control functions The internal LVD relay is in series with the BATT terminal Check that all connections to the charger are correct and tight r...

Page 8: ...e the display between output current and battery current measurements Each step of the bar graph represents a 10 increment in current Note that the display will turn off approximately 15 minutes after...

Page 9: ...ent has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules and ICES 003 These limits are designed to provide reasonable protection agains...

Page 10: ...2 4A 4 8A 2 4A 4 8A Idle DC Power Draw5 200mW 200mW 200mW 200mW 200mW 3 Stage Charge Parameters at 25 C Absorb V AGM 14 55 14 55 29 1 29 1 58 2 Flooded 14 4 14 4 28 8 28 8 57 6 Gel 14 2 14 2 28 4 28...

Page 11: ...ector 2 pins on 5 pin plug Operating Temperature Range 30C to 60 C6 Storage Temperature Range 40 to 70 C Humidity Operating 10 90 non condensing Storage 5 95 non condensing Cooling Temperature control...

Page 12: ...bsite at www ict power com support warranty repair The Purchaser shall at their own risk and cost return the defective product to ICT s factory or designated repair center once an RMA is issued by ICT...

Page 13: ...ermal or electrical stress improper maintenance or causes external to the unit including but not limited to general environmental conditions such as rust corrosive atmospheres sustained temperatures o...

Reviews: