3.2.8 LoRaWAN Maximum TX Power – lora tx power
Command Input:
lora tx power
Compatible:
All Device Firmware Versions
Description:
Manage the device’s default maximum transmit power. This is relative to the maximum EIRP,
which can be changed by the network server after the device is joined to the network.
The actual maximum transmit power will be the maximum EIRP minus 2 times this setting, in dBm, unless
that value is above 20 dBm, as that is the maximum power of the device’s radio.
3.2.9 Confirmed Messaging – lora confirmed
Command Input:
lora confirmed
Compatible:
All Device Firmware Versions
Description:
Enables/Disables LoRaWAN confirmed messaging.
Command
Type
Syntax Used
Example Command
Response
Type
Example Result of Command
Get
lora tx power
lora tx power
<power>
0
Set
lora tx power
<power>
lora tx power 2
<power>
lora tx power 2 2
Parameter Type
Description
<power>
Number
Maximum transmit power, power below MAX_EIRP.
TX_PWR = MAX_EIRP – 2 x power (dBm)
Command
Type
Syntax Used
Example Command
Response
Type
Example Result of Command
Get
lora confirmed
lora confirmed
<string>
disabled
Set
lora confirmed
<bool>
lora confirmed
0
<status>
lora net adr 0 disabled
Parameter Type
Description
<bool>
Number
Indicates whether to enable or disable confirmed messaging:
0
: Disable
1
: Enabled
ICT INTERNATIONAL
Enabling better global research outcomes in soil, plant & environmental monitoring