69
«
Sort Sensor Error
»
Code: E18
LED Light Display: 3 red + 4 red
LCM Display: As shown in figure below
Cause: Coin separator sensor problem.
Corrective Measure:
1. Make sure that the reflective prism is not dirty or blocked by foreign objects. If
it is, remove the foreign object and clean the reflective prism.
2. Changer retries once a minute for 10 times when error is detected. It will stop if
the problem is not resolved after 10 times retry.
Sorting Module
Sensor Error E18