background image

Manual Number: 00750-004-14

Page 1-2

DB37S

DB25P

PINOUT

PLUG/PIN

ATTRIBUTE

1

P4-8

DCD

2

P4-3

RD

3

P4-2

TD

4

P4-20

DTR

5

P4-7

GND

6

P3-22

RI

7

P3-5

CTS

8

P3-4

RTS

9

P3-6

DSR

10

P2-8

DCD

11

P2-3

RD

12

P2-2

TD

13

P2-20

DTR

14

P2-7

GND

15

P1-22

RI

16

P1-5

CTS

17

P1-4

RTS

18

P1-6

DSR

19

NO CONNECTION

20

P4-6

DSR

21

P4-4

RTS

22

P4-5

CTS

23

P4-22

RI

24

P3-7

GND

25

P3-20

DTR

26

P3-2

TD

27

P3-3

RD

28

P3-8

DCD

29

P2-6

DSR

30

P2-4

RTS

31

P2-5

CTS

32

P2-22

RI

33

P1-7

GND

34

P1-20

DTR

35

P1-2

TD

36

P1-3

RD

37

P1-8

DCD

DB-25  PORT 1 - PORT 4 PINOUTS
SIGNAL

          NAME                             PINOUT

     MODE

TD

TRANSMIT DATA

2

OUTPUT RS-232

RTS

REQ. TO SEND

4

OUTPUT RS-232

RD

RECEIVE DATA

3

INPUT RS-232

CTS

CLEAR TO SEND

5

INPUT RS-232

GND

GROUND

7

DCD

DATA CARRIER DETECT

8

INPUT RS-232

DSR

DATA SET READY

6

INPUT RS-232

DTR

DATA TERMINAL READY

20

OUTPUT RS-232

RI

RING INDICATOR

22

INPUT RS-232

Figure 1-1:  Board to Port Pinouts

To WINCOMM4 Board

DB37S Connector

PORT 4      PORT 3     PORT 2     PORT 1

DB25P Connectors

User Defined Serial Ports/Devices

aprox. 36 in

(914.4mm)

Summary of Contents for WINCOMM4

Page 1: ...Model WINCOMM4 Product Manual MANUAL NUMBER 00750 004 14C...

Page 2: ...ual in our online Support Library Thank you The information in this document is provided for reference only ICS Advent does not assume any liability arising from the application or use of the informat...

Page 3: ...ts which are not in an as new and re saleable condition are not eligible for credit return and will be returned to the customer Limited Warranty Effective April 1 1998 all products carry a 2 year limi...

Page 4: ...made by various manufacturers in performing warranty repairs and building replacement products If ICS Advent repairs or replaces a product its warranty term is not extended ICSAdvent will normally ret...

Page 5: ...Cautions and Warnings are accented with triangular symbols The exclamation symbol is used in all cautions and warnings to help alert you to the important instructions The lightning flash symbol is us...

Page 6: ...lection 3 1 Port Enable Disable 3 1 Chapter 4 Technical Description 4 1 WINCOMM4 Four Port RS 232 Serial Interface 4 1 Features 4 1 How to remain CE Compliant 4 1 Chapter 5 Specifications 5 1 Declarat...

Page 7: ...ts except J8 on the original IBM XT and portable Be sure to set the address and jumper options before installation Remove the PC case remove the blank metal slot cover and insert the board Replace the...

Page 8: ...CD 29 P2 6 DSR 30 P2 4 RTS 31 P2 5 CTS 32 P2 22 RI 33 P1 7 GND 34 P1 20 DTR 35 P1 2 TD 36 P1 3 RD 37 P1 8 DCD DB 25 PORT 1 PORT 4 PINOUTS SIGNAL NAME PINOUT MODE TD TRANSMIT DATA 2 OUTPUTRS 232 RTS RE...

Page 9: ...0 1 0 1 X X X 0 F F O N O F F O N O F F O N O N O 2 M O C F F 2 8 F 2 1 1 1 1 0 1 X X X 1 F F O N O F F O F F O F F O F F O F F O 1 M O C F F 3 8 F 3 1 1 1 1 1 1 X X X 1 F F O F F O F F O F F O F F O...

Page 10: ...Position Address Line Example 300 Hex Switch 1 A9 1 OFF 2 A8 1 OFF 3 A7 0 ON 4 A6 0 ON 5 A5 0 ON 6 A4 0 ON 7 A3 0 ON Note that setting the switch ON or CLOSED corresponds to a 0 in the address while...

Page 11: ...tting If COM2 is selected this jumper must be on IRQ3 NOTE Most communications software applications default COM3 to IRQ4 and COM4 to IRQ3 This requires the sharing of interrupts between COM1 and COM3...

Page 12: ...ows more than one port to access a single IRQ The M indicates the inclusion of a 1K OHM pull down resistor required on one port when sharing interrupts E5 M M S S N N Set the jumpers to N for single i...

Page 13: ...if you are using more than one WINCOMM4 in a BUS or you wish to completely remove the pull down resistor for hardware compatibility Setting the board in this configuration when it is not accompanied b...

Page 14: ...ake signals such as CTS or DCD Consult the particular manual for your software to determine these requirements If none are mentioned or if you are not sure a safe configuration is to tie DTR to DSR an...

Page 15: ...Range 0 90 R H Non Conddensing 0 90 Non Condensing Performance MTBF 150 000 Hours Manufacturing IPC 610 A Class III standards adhered to with 0 1 visual A Q L and 100 Functional Testing Boards are bu...

Page 16: ...munity EN61000 4 3 1995RadiatedRFFieldImmunity EN61000 4 4 1995EFTImmunityforACandI OLines EN 60950 1992 Safety of InformationTechnology Equipment Thetechnicaldocumentationrequiredtodemonstratethispro...

Reviews: