MDS Diagnostic Code Entry
• Enter RAS mode
• MDS Sensor – diagnostic code
60
• Enter code by pressing the SW1 switch until a
“6” appears in the ten’s display
• Press ST switch twice to start test
• A code will be displayed (Ex)
• Adjust MDS sensor to achieve a value of E7 +4
• Exit RAS mode after adjustment is within
specifications
Adjustments to the MDS sensor should only be made by
an ICS Technician unless authorized by ICS Support
Level 2
Summary of Contents for Auto Sentry-eXP
Page 1: ...Auto Sentry eXP Maintenance Revised 12 21 07...
Page 32: ...Sensor Location TOP FRONT...
Page 46: ...PS1 Sensor PSI Sensor Prism location Viewed from back of Bill Dispenser...
Page 52: ...PS1 Sensor Cleaning Remove two screws from Close tab bracket Push up on Open tab to release...
Page 63: ...Pick Assembly Cleaning Level 2...
Page 66: ...Opening the Close Tab Area Remove the two screws on the Close Tab and fold down Level 2...
Page 67: ...Clean the entire area Blow off the Dust Clean all rollers Metal Rubber Level 2...
Page 78: ...Reinstall the Pick Assembly Level 2...
Page 86: ...Proper Drive Belt Configuration shown with cover removed Level 2...
Page 87: ...Credit Card Reader Maintenance Removing Foreign Objects Credit Card Reader Cleaning Procedure...
Page 90: ...Credit Card Reader Foreign Object Removal...
Page 99: ...Bill Acceptor Maintenance Bill Acceptor Maintenance Bill Acceptor Cleaning Procedure...
Page 100: ...Bill Acceptor Status LED...
Page 101: ...Bill Acceptor Status LED...
Page 102: ...Bill Acceptor Status LED...
Page 103: ...Bill Acceptor Status LED...
Page 104: ...Bill Acceptor Status LED...
Page 105: ...Bill Acceptor Connector Pin outs Cartridge Side...