background image

Thank you for purchasing the USB 3.0 Spectra

 3022. 

Please read this guide thoroughly.

This document applies to Part Numbers: 00-00327, 00-00328, 00-00329, and 00-00330.

FCC Radio Frequency Interference Statement Warning

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:  
(1) this device may not cause harmful interference, and (2) this device must accept any interference received 
including interference that may cause undesired operation.

CE Statement

We, Icron Technologies Corporation, declare under our sole responsibility that the Spectra 3022, to which 
this declaration relates, is in conformity with European Standard EN 55022, EN 55024, EN 61000-3-2, and 
EN 61000-3-3.  

IC Statement

This Class B digital apparatus complies with Canadian ICES-003.

©2013 Icron Technologies Corporation. All rights reserved. Icron Technologies Corporation, the Icron 
Technologies Corporation logo, and the Icron Technologies Corporation products referred to herein are 
either the trademarks or the registered trademarks of Icron Technologies Corporation. All other trademarks 
are property of their respective owners. Icron Technologies Corporation assumes no responsibility for errors 
that may appear in this manual. Information contained herein is subject to change without notice. 

Document #90-01057-A04

Summary of Contents for Spectra 3022

Page 1: ...USB 3 0 Spectra 3022 2 Port USB 3 0 100m Multimode Fiber Extender System User Guide ...

Page 2: ...sibility that the Spectra 3022 to which this declaration relates is in conformity with European Standard EN 55022 EN 55024 EN 61000 3 2 and EN 61000 3 3 IC Statement This Class B digital apparatus complies with Canadian ICES 003 2013 Icron Technologies Corporation All rights reserved Icron Technologies Corporation the Icron Technologies Corporation logo and the Icron Technologies Corporation produ...

Page 3: ... Your Site 7 Preparing Your Computer 7 Connecting a USB 3 0 Device 11 Installing the REX Unit 11 Installing the LEX Unit 11 Checking the Installation 12 Compatibility 12 Troubleshooting 13 Contacting Technical Support 15 Warranty Information 15 Obtaining Warranty Service 16 Contacting Sales 16 Contacting Technical Support 16 Technical Glossary 17 USB Connectors 17 Duplex LC Crossover 17 Specificat...

Page 4: ...ional requirement Spectra 3022 Product Contents Your Spectra 3022 is packaged with LEX Local Extender REX Remote Extender REX AC power adapter USB 3 0 cable Country specific power cable Quick Start Guide and Warranty Information Features The Spectra 3022 incorporates Icron s patented ExtremeUSB technology enabling users to extend beyond the standard 3m cable limit for USB 3 0 peripheral devices Wi...

Page 5: ...Fault detected power cycle required 3 Host ON SuperSpeed Host detected on upstream facing port Host OFF SuperSpeed Host not detected 4 Power Port optional Not required in normal operation An optional 5V power supply can be connected to the LEX unit to provide power if the USB port on the host PC is not capable of delivering sufficient power to the unit 5 Config Port Reserved for manufacturer use 6...

Page 6: ...or non locking USB 3 0 Type A connectors 2 Power ON Unit is powered properly Power OFF Unit is not powered or not powered properly 3 Status Blinking 1Hz Waiting for connection to LEX Status ON LEX REX are linked and operating normally Status OFF Fault detected power cycle required 4 Host ON SuperSpeed Host detected on upstream facing port Host OFF SuperSpeed Host not detected 5 Power Port Connects...

Page 7: ...cabling This cabling must be 50 125μm multimode fiber MMF Terminated with Duplex LC connectors The following maximum distances are achievable depending on the application and cabling standard Using OM3 up to 100m is achievable with USB 3 0 cameras and up to 50m for all other applications Using OM2 up to 50m is achievable for all applications note For assistance sourcing appropriate fibre optic cab...

Page 8: ...s 3 Ensure fiber optic cabling is in place prepared properly terminated and within the maximum distances as defined for the cabling standard used Preparing Your Computer The Spectra 3022 does not support suspend modes of operation As such your computer should be configured to not go into suspend mode or to suspend the USB ports To perform the changes Windows 7 8 To disable suspend settings on your...

Page 9: ...8 For each of the plans listed a Click on Change Plan Settings 2 Select Never for Put the computer to sleep for all the configurations presented a Click Change advanced power settings ...

Page 10: ...9 b Expand USB settings c Expand USB selective suspend setting 3 Select Disabled OS X To disable suspend settings on your computer 1 Open System Preferences and select Energy Saver ...

Page 11: ...2 For both Battery and Power Adapter power settings move slider bar to Never for Computer Sleep 3 In the popup warning window click OK 10 ...

Page 12: ...e to the LEX and the REX With Surface Cabling Plug one end of the fiber optic cabling not included into the Link port on the LEX Plug the other end of the fiber optic cabling into the Link port on the REX With Premise Cabling Plug one end of a fiber optic patch cord not included into the Link port on the LEX Plug the other end of the patch cord into the fiber optic information outlet near the host...

Page 13: ...installed correctly you should find it listed as a Hub under the USB SuperSpeed Bus 4 If the Spectra 3022 is not detected correctly or fails to detect please consult the Troubleshooting section in this guide To open System Profiler in OS X Open the Finder select Applications then open the Utilities folder and double click on the System Profiler icon To open Device Manager in Windows 8 or Windows 7...

Page 14: ...e is no connection between the LEX and REX The LEX is not connected to a USB 3 0 port The host computer does not support USB 3 0 1 Ensure that the host computer supports USB 3 0 refer to manual for the computer to confirm 2 Ensure the LEX is connected to a USB 3 0 port The centre of the port should be blue Another colour such as black usually indicates a USB 2 0 port 3 Ensure that a multimode fibe...

Page 15: ...y or is detected as an Unknown Device in the operating system The USB device is malfunctioning The computer does not recognize the USB device The application software for the device is not operating The Spectra 3022 is malfunctioning 1 Disconnect the Spectra 3022 from the computer 2 Connect the USB device directly to the USB port on the computer 3 If the USB device does not operate properly consul...

Page 16: ...rdware has resulted from accident abuse or misapplication Limitation of Liability The hardware warranty set forth in this agreement replaces all other warranties Icron Technologies Corporation expressly disclaims all other merchantability and fitness for a particular purpose and noninfringement of third party rights with respect to the hardware Icron Technologies Corporation dealer agent or employ...

Page 17: ...e outside of the package The package must be sent prepaid to Icron Technologies Corporation We recommend that you insure it or send it by a method that provides for tracking of the package The repaired or replaced item will be shipped to you at Icron Technologies Corporation s expense not later than thirty days after Icron Technologies Corporation receives the defective product Address the returni...

Page 18: ...ectors USB 3 0 and USB 2 0 Type A connectors are the same shape and size and are compatible with each other However the USB 3 0 Type B connector will not fit in a USB 2 0 Type B port though a USB 2 0 Type B connector will fit into a USB 3 0 Type B port Duplex LC Crossover When a crossover fiber optic cable is called for the cable has the transmit signal on one end connected to the receive signal a...

Page 19: ...tors 1 x Duplex LC Connector Dimensions 100mm x 76mm x 26mm 3 94 x 2 99 x 1 02 REX Remote Extender USB Connectors 2 x USB 3 0 Type A Locking Receptacles Link Connectors 1 x Duplex LC Connector Dimensions 100mm x 76mm x 26mm 3 94 x 2 99 x 1 02 ENVIRONMENTAL Operating Temperature Range 0 C to 40 C 32 F to 104 F Storage Temperature Range 20 C to 70 C 4 F to 170 F Operating Humidity 20 to 80 relative ...

Page 20: ...Icron Technologies Corporation 4664 Lougheed Highway Suite 221 Burnaby BC Canada V5C 5T5 Tel 1 604 638 3920 Fax 1 604 638 3930 icron com ...

Reviews: