![ICPDAS PDS-811 User Manual Download Page 63](http://html.mh-extra.com/html/icpdas/pds-811/pds-811_user-manual_614813063.webp)
Programmable Device Server with I/O Expansion Slot(s)
PDS-8x1 Series User Manual, Version 1.1.2, Apr. 2015
-
63 -
The following are examples of pair-connection tests:
Pair-connection Settings:
Model
Port Settings
(default)
Pair-connection Settings
COM
Port
Baud
Rate
Data
Format
Remote
Server IP
Remote TCP Port
(default)
PDS-8x1 #1
(Client Mode)
COM1
9600
8N1
IP Address of PDS-8x1 #2
10001
PDS-8x1 #2
(Server Mode)
COM1
9600
8N1
-
-
Follow the procedure described below:
Step 1: Connecting to a network, PC and Power
1.
Confirm that the PDS-8x1 controllers are functioning correctly. Refer to
Chapter 3 Setting up the
PDS-8x1 controller
for more details.
2.
Connect COM1 of the PC to COM1 of the PDS-8x1 #1, and then connect COM2 of the PC to
COM1 of the PDS-8x1 #2. For detailed RS-232 wiring information, refer to
Section 2.7 “Wiring
Notes for RS-232/485/422 Interfaces”
.
3.
24 V
DC
(+10 ~ +30 V
DC
) power to the PDS-8x1 controller.
※
Refer to
Figure 5-3.1
for an illustration of how to perform the above steps.
Note:
The Baud Rate and Data Format settings of the client and server (PDS-8x1 #1 and #2) depend
on the COM ports of the PC (or the connected device).