78
x1, y1:
host adapter number, SCSI ID
of the first SCSI device to be reserved
(in decimal form)
x2, y2:
host adapter number, SCSI ID
of the second SCSI device to be reserved
(in decimal form)
Example: We assume that there is only one ICP Controller in the system. Two
direct access
devices
, the removable hard disk connected to channel A, ID 2, and the hard disk connected
to channel B, ID 4, have to be reserved for the ASPI manager. The corresponding entry in
the CONFIG.SYS is:
DEVICE=GDTASPI.EXE /R:H0I2:H1I4
Important note: SCSI devices reserved for the ASPI manager must not have been initialized
with ICPCON. Neither must they pertain to an ICP Logical or Host Drive. If necessary, these
devices can be de-initialized with ICPCON.
As already mentioned in paragraph 6 of this chapter, in addition to the ASPI manager an
ASPI module has to be present in order to be able to access the SCSI device under MS-DOS
with a drive name (e.g., D, E, etc.). In the following description you find how to install ASPI
interface-reserved
direct access devices
with the ASW ASPI module ASPIDISK.SYS and the
corelSCSI ASPI module UNI_ASP.SYS.
D.6.1 Using ASW ASPIDISK.SYS
Step 1
:
Include GDTX0000.EXE, GDTASPI.EXE with appropriate reservations (../R:..), and
ASPIDISK.SYS in the CONFIG.SYS file, then do a warm reboot (Ctrl+Alt+Del).
Step 2
:
Use the ASW program AFDISK.EXE to initialize the drive to be run through the ASPI
interface.
Step 3:
After the successful initialization, do a warm reboot (Ctrl+Alt+Del).
The CONFIG.SYS will be similar to the following (the relevant entries are printed bold):
device=gdtx000.exe
files=30
buffers=30
stacks=9,256
shell=\COMMAND.COM /E:512 /P
device=\gdt\gdtxdos.exe
device=\gdt\gdtaspi.exe /R:H1I4
device=aspidisk.sys
Note: Drives run with ASPIDISK.SYS are not compatible with drives run with ICPCON.
D.6.2 Using corelSCSI
Step 1
:
Include GDTX0000.EXE, GDTASPI.EXE with appropriate reservations (../R:..) in the
CONFIG.SYS file, then do a warm reboot (Ctrl+Alt+Del).
Step 2
:
Load corel’s
Install
program and follow the instructions. Preferably, use
Express-Setup
.
Step 3
:
After the successful installation, do a warm reboot (Ctrl+Alt+Del).
Step 4
:
Using the corelSCSI program CFORMAT, format the drive to be run through the
ASPI interface.
The CONFIG.SYS will be similar to the file below (the relevant entries are printed bold). The
parameters following the corelSCSI driver refer to a particular configuration, they have
automatically been added by the corelSCSI INSTALL program.
device=gdtx000.exe
files=30
Summary of Contents for RS Series
Page 2: ...2...
Page 14: ...14...
Page 16: ...16...
Page 36: ...36...
Page 42: ...42 Example for a SCSI Flat Ribbon Cable for 8 Bit SCSI Devices narrow...
Page 43: ...43 Example for a SCSI Flat Ribbon Cable for 16 Bit SCSI Devices wide...
Page 53: ...53 Chapter C C C C Quick Quick Quick Quick S e t u p S e t u p S e t u p S e t u p...
Page 54: ...54...
Page 69: ...69 Replacement either manually or through hot fix method...
Page 71: ...71 Chapter D D D D Using Using Using Using M S D O S M S D O S M S D O S M S D O S...
Page 72: ...72...
Page 82: ...82...
Page 83: ...83 Chapter E E E E Using Using Using Using NetWare NetWare NetWare NetWare...
Page 84: ...84...
Page 92: ...92...
Page 99: ...99 Chapter G G G G Using Using Using Using L I N U X L I N U X L I N U X L I N U X...
Page 100: ...100...
Page 105: ...105 Chapter H H H H Using Using Using Using SCO UNIX SCO UNIX SCO UNIX SCO UNIX...
Page 106: ...106...
Page 113: ...113 Chapter I I I I Using Using Using Using Uni Uni Uni Unix x x xWare Ware Ware Ware...
Page 114: ...114...
Page 118: ...118...
Page 119: ...119 Chapter J J J J ICP RAID ICP RAID ICP RAID ICP RAID Console Console Console Console...
Page 120: ...120...
Page 152: ...152...
Page 154: ...154...
Page 189: ...189 Chapter L L L L Appendix Appendix Appendix Appendix...
Page 190: ...190...