60
C.2.2 Levels of Hierarchy Within the ICP Firmware
The ICP firmware is based on four fundamental levels of hierarchy. Each level has its "own
drives" ( = components). The basic rule is:
To build up a “drive“ on a given level of hierarchy, the “drives“ of the next lower
level of hierarchy are used as components.
Level 1:
Physical Drives
= hard disks, removable hard disks, some MO drives are located on the
lowest level. They are the basic components of all "drive constructions" you can set up.
However, before they can be used by the firmware, these hard disks must be "prepared", a
procedure we call
initialization
. During this initialization each hard disk receives information
which allows a univocal identification even if the SCSI-ID or the controller is changed. For
reasons of data coherency, this information is extremely important for any drive construc-
tion consisting of more than one physical drive.
Level 2:
On the next higher level are the
Logical Drives
. Logical Drives are introduced to obtain full
independence of the physical coordinates of a physical device. This is necessary to easily
change the whole ICP Controller and the channels, IDs, without loosing the data and the
information on a specific disk array.
Level 3:
On this level of hierarchy, the firmware forms the
Array Drives
. Depending on the firmware
installed, this can be
-
Single Disks (one hard disk, some vendors call it JBOD - Just A Bunch Of Drives)
-
Chaining Sets (concatenation of several hard disks)
-
RAID 0 Array Drives
-
RAID 1 Array Drives, RAID 1 Array Drives plus hot fix drive
-
RAID 4 Array Drives, RAID 4 Array Drives plus hot fix drive
-
RAID 5 Array Drives, RAID 5 Array Drives plus hot fix drive
-
RAID 10 Array Drives, RAID 10 Array Drives plus hot fix drive
Level 4:
On the highest level of hierarchy, the firmware forms the
Host Drives
. In the end, only
these Host Drives can be accessed by the host operating system of the computer. Drives C,
D, etc. under MS-DOS etc. are always referred to as Host Drives by the firmware. The same
applies to NetWare- and UNIX-drives. The firmware automatically transforms each newly
installed Logical Drive and Array Drive into a Host Drive. This Host Drive is then assigned a
Host Drive number which is identical to its Logical Drive or Array Drive number.
The firmware is capable of running several Host Drives of the most various kinds at the
same time. An example for MS-DOS: drive C is a RAID 5 type Host Drive (consisting of 5
SCSI hard disks), drive D is a single hard disk, and drive E is a CD-ROM communicating
with RAIDYNE® through corelSCSI and the GDT ASPI manager.
On this level the user may split an existing Array Drive into several Host Drives.
After a capacity expansion of a given Array Drive the added capacity appears as a new Host
Drive on this level. It can be either used as a separate Host Drive, or merged with the first
Host Drive of the Array Drive. Within ICPCON, each level of hierarchy has its own special
menu:
Level 1
Ö
Menu:
Configure Physical Devices
Level 2
Ö
Menu:
Configure Logical Drives
Level 3
Ö
Menu:
Configure Array Drives
Level 4
Ö
Menu:
Configure Host Drives
Summary of Contents for RS Series
Page 2: ...2...
Page 14: ...14...
Page 16: ...16...
Page 36: ...36...
Page 42: ...42 Example for a SCSI Flat Ribbon Cable for 8 Bit SCSI Devices narrow...
Page 43: ...43 Example for a SCSI Flat Ribbon Cable for 16 Bit SCSI Devices wide...
Page 53: ...53 Chapter C C C C Quick Quick Quick Quick S e t u p S e t u p S e t u p S e t u p...
Page 54: ...54...
Page 69: ...69 Replacement either manually or through hot fix method...
Page 71: ...71 Chapter D D D D Using Using Using Using M S D O S M S D O S M S D O S M S D O S...
Page 72: ...72...
Page 82: ...82...
Page 83: ...83 Chapter E E E E Using Using Using Using NetWare NetWare NetWare NetWare...
Page 84: ...84...
Page 92: ...92...
Page 99: ...99 Chapter G G G G Using Using Using Using L I N U X L I N U X L I N U X L I N U X...
Page 100: ...100...
Page 105: ...105 Chapter H H H H Using Using Using Using SCO UNIX SCO UNIX SCO UNIX SCO UNIX...
Page 106: ...106...
Page 113: ...113 Chapter I I I I Using Using Using Using Uni Uni Uni Unix x x xWare Ware Ware Ware...
Page 114: ...114...
Page 118: ...118...
Page 119: ...119 Chapter J J J J ICP RAID ICP RAID ICP RAID ICP RAID Console Console Console Console...
Page 120: ...120...
Page 152: ...152...
Page 154: ...154...
Page 189: ...189 Chapter L L L L Appendix Appendix Appendix Appendix...
Page 190: ...190...