iDRY Series Heatless Regenerated Dryers: IOM10003-C
(Rev. A)
6
Before any attempt is made to operate the dryer, the operator must thoroughly read and understand this
installation and operation manual.
Optimal Installation Diagram
1
Air Compressor
2
After Cooler
3
iPUR Inline Water Separator
4
iPUR 5.0 Micron (Grade G) Filtration
5
Receiver Tank
6
iPUR 1.0 Micron (Grade F) Filtration
7
iDRY iDHLBe Desiccant Dryer with iPUR Pre and Post-filtration
8
Dry Air Outlet
9
Condensate Drainage Points for iMAT
Optimal
installation is with moderately sized receivers at the inlet and outlet side of the dryer. This allows for the
additional free cooling and moisture collection and more consistent dryer inlet flow provided by an upstream receiver,
while providing the most reliable shop air supply due to the downstream receiver.
Under no circumstances should the peak demand air flow exceed the maximum rated air flow of the dryer.
We recommend the dryer be installed with a 0.01 micron iPUR coalescing pre-filter at the inlet and a 1
micron iPUR particulate post-filter at the outlet. It is recommended to install both 5 micron and 1 micron
filters upstream of the dryer in order to maintain the operational lifespan of the inlet filter.
2.4
Mounted Filters with Bypass
Mounted Filters with Bypass is an optional setup for the heatless regenerative
dryer. The three valve system bypass allows for the flow of air to be uniterupted
while servicing or completing preventative maintinance such as:
Exchange pre- and post- filters
Services exhaust sIlencers
Change desiccant