background image

25

PARTS LIST

Model: MBOV115DABR-D

ITEM

PART #

DESCRIPTION

COMMENTS

1

B40119-01

Complete heat exchanger

Item 24 included; item 46 not included

2

B40067

Top baffle

3

R02I007

Fan Limit Control L6064A

4

B40460

Component panel

Items 5, 6 and 7 not included

5

L01H009

Relay SPDT 24 VAC

6

L05F009

Terminal strip, 4 positions

7

L01F009

Transformer 120-24 VAC, 40 VA

8

B40464-01

Electrical box cover

9

B02282

Observation door

10

B40048

Burner panel assembly

Items 7 and 14 included

11

F07O001

Hexagonal flange nut 3/8-16NC brass

18 required

12

B40140

Electrical box assembly

Box only

13

B40463-02

Electrical cover assembly

Item 14 not included, labels included

14

L07F003

Rocker switch

15

B40148

Vestibule burner assembly

16

B40455

Burner electrical kit

17

F07F024

Hexagonal nut 3/8-16NC brass

4 required

18

F06F005

Washer 3/8" AA zinc

4 required

19

B40120

Air supply door

20

B40030

Gasket, burner panel

21

B40099

Heat shield assembly

Insulation included

22

B40070-01

Corner conduit

23

L04I013

Strain relief bushing

24

B40146

Front panel assembly

Item 25 included

25

B40126

Front panel insulation

26

B40160

Combustion chamber

27

B00891-50

Strap 10' x 1/2"

28

Z05F009

Combustion chamber strap seal

29

B40129

Floor assembly

Item 30 included

30

B01526-78

Floor insulation

31

B40133

Divison panel assembly

Central support, rear baffle and item 32 included

32

B01291-02

Seal strip

3 required

33

B40131-02

Left side panel assembly

Item 34 included

34

B40125-02

Left side panel insulation

35

L04G005

Bushing 1 3/8''

36

B40132

Blower door assembly

Item 37 included

37

Z99F050

Door handle

38

B40492

Top rear panel

39

B40032

Gasket, smoke outlet

40

B40046

Smoke outlet assembly

41

B40054-01

Baffle assembly

3 required

42

B40043

Plenum divider

43

B40076

Top division panel

44

B40410

Filter rack assembly

45

Z04F004

20 X 20 X 1 paper filter

46

B40131-01

Right side panel assembly

Item 47 included

47

B40125-01

Right side panel insulation

48

J06L002

Seal strip 1/4" X 1/8" x 25'

49

L06G011

1/3 HP direct drive motor

50

B01888

Motor mount assembly

Legs, band and screws included

51

Z01F006

Rubber grommet

4 required

52

B01756

Blower support bracket

53

B40456

Blower electrical kit

54

L04I010

Strain relief bushing

55

B40059

Terminal strip cover

Item 57 not included

56

L03J005

Terminal plug-in 0.250

57

L99F003

Terminal block 4 positions

58

B40074

Terminal strip support

59

L04G013

Bushing 7/8"

1 required

60

B01024

Capacitor holder

61

L01I003

10 MF capacitor

62

B40135-01

Blower assembly

Items 49 to 64 included

63

Z01I001

Blower 10 X 10

Housing and wheel included

64

Z01L004

Blower wheel 10 X 10

65

B03118-01

Electrical kit for BVSO

66

Z06G001

Blocked vent shut off BVSO

67

L04I005

Strain relief bushing

68

A00183-01

Observation door spring

69

F03F023

Screw #F hex wsh 1/4-20 x 1 1/4             

L50041B

445 01 4054 06

Summary of Contents for FLO115DABR-C

Page 1: ...5DABR D OLF140C12C OLR182A16C D N S 0 5 9 4 R v A D N S 0 6 6 5 R v A D N S 0 5 7 5 R v A Manufactured by UTC Canada Corporation ICP Division 3400 Industrial Boulevard Sherbrooke Quebec Canada J1L 1V8...

Page 2: ...ician familiar with safety procedures and equipped with the proper tools and test instruments Failure to carefully read and follow all instructions in this manual can result in death and or personal i...

Page 3: ...mber Normal servicing of this unit does not require cleaning of the combustion chamber Use extreme care if for any reason you have to work in the area of the combustion chamber 1 2 2 Freezing temperat...

Page 4: ...r size and adequate chimney base temperature as specified in the Installation Code The relevant excerpt from the code is found in this section Use it as a guide when local or national codes do not exi...

Page 5: ...o provide adequate combustion and ventilation air can result in death and or personal injury 1 5 1 General Oil furnaces must have an adequate supply of combustion air It is common practice to assume t...

Page 6: ...vinyl vapour barrier CAUTION The CAS 2B does not turn the furnace installation into a direct vent system Therefore the building structure must provide for adequate combustion air to be delivered to t...

Page 7: ...heat exchanger warranty intact WARNING Fire and explosion hazard Use only approved heating type oil in this furnace DO NOT USE waste oil used motor oil gasoline or kerosene Use of these will result in...

Page 8: ...here the furnace is located Install the air conditioning cooling coil evaporator downstream from the supply air plenum of the furnace If a separate evaporator and blower unit is used install appropria...

Page 9: ...off the disconnect switch and CALL A QUALIFIED SERVICE TECHNICIAN CAUTION Do not attempt to start the burner when excess oil has accumulated when the furnace is full of vapour or when the combustion c...

Page 10: ...nd blower regulator Modification of the FAN ON and HI Limit settings on the Fan Limit and blower regulator can cause a malfunction of the furnace and carry to premature wear of the heat exchanger CAUT...

Page 11: ...inder with a stiff brush and vacuum cleaner 7 The heat exchanger and combustion chamber should be inspected to determine if replacement is required before re assembling the unit 8 After cleaning repla...

Page 12: ...ntion head 3 1 5 Nozzle Replace the nozzle with the one specified in Tables 3 1 to 3 4 p 15 to 18 3 1 6 Oil filter Tank filter The tank filter should be replaced as required Secondary filter The 10 mi...

Page 13: ...e Day Night Dealer name and address START UP TEST RESULTS Nozzle Pressure Lb psi Burner adjustments Primary air Fine air Draw Assembly CO2 Smoke scale Bacharach Gross stack temperature F Ambient tempe...

Page 14: ...5 1 2 75 2 3 75 AERO BURNER 1725 RPM Nozzle 100 PSIG pump pressure Delavan 0 65 70W 0 75 70W 0 85 70W Volts Hertz Phase Operating voltage range Rated voltage Amps Minimum ampacity for wiring sizing Ma...

Page 15: ...Nozzle Delavan 060 60W 075 60W 0 85 60W 0 85 60W Pump pressure PSIG 155 130 140 170 Combustion air adjustment turbulator damper 2 3 25 2 5 4 2 2 5 3 2 5 AERO BURNER 1725 RPM Nozzle 100 PSIG pump press...

Page 16: ...6 6 RIELLO BURNER MODEL 40 Nozzle Delavan 0 85 60W 0 85 60W 1 00 60W 1 10 60W Pump pressure PSIG 140 170 145 140 Combustion air adjustment turbulator damper 2 5 2 5 3 2 75 3 3 3 5 3 25 AERO BURNER 172...

Page 17: ...er 1 5 2 75 2 5 3 25 3 4 25 AERO BURNER 1725 RPM Nozzle 100 PSIG pump pressure Delavan 0 75 70W 0 85 70W 1 00 70W ELECTRICAL SYSTEM Volts Hertz Phase Operating voltage range Rated voltage Amps Minimum...

Page 18: ...19 DNS 0596 Rev D FIGURE 4 2 Model MBOV115DABR D FIGURE 4 1 Model MBO115DABR D DNS 0590 Rev D 445 01 4054 06...

Page 19: ...20 FIGURE 4 3 Models LBO125DABR13 D LBO145DABR34 D OLR182A16C FIGURE 4 4 Model FLO115DABR C OLF140C12C DNS 0666 Rev C DNS 0576 Rev F 445 01 4054 06...

Page 20: ...21 FIGURE 5 Wiring diagram MBO115DABR D MBOV115DABR D LBO125DABR13 D LBO145DABR34 D OLR182A16C FLO115DABR C OLF140C12C DNS 1014 Rev A 445 01 4054 06...

Page 21: ...22 PARTS LIST Model MBO115DABR D B50040B 445 01 4054 06...

Page 22: ...B40492 Top rear panel 30 B40032 Gasket smoke outlet 31 B40046 Smoke outlet assembly 32 B40054 01 Baffle assembly 5 required 33 B40043 Plenum divider 34 B40076 Top division panel 35 B40410 Filter rack...

Page 23: ...PARTS LIST Model MBOV115DABR D B50041B 445 01 4054 06...

Page 24: ...ntral support rear baffle and item 32 included 32 B01291 02 Seal strip 3 required 33 B40131 02 Left side panel assembly Item 34 included 34 B40125 02 Left side panel insulation 35 L04G005 Bushing 1 3...

Page 25: ...26 PARTS LIST Model LBO125DABR13 D B50038C 445 01 4054 06...

Page 26: ...32 B40032 Gasket smoke outlet 33 B40046 Smoke outlet assembly 34 B40071 Inlet baffle 2 required 35 B40043 Plenum divider 36 B40054 01 Baffle assembly 5 required 37 B40108 Division panel assembly Centr...

Page 27: ...PARTS LIST Models LBO145DABR34 D OLR182A16C B50039F 445 01 4054 06...

Page 28: ...B40107 01 Blower door assembly Item 29 included 29 Z99F050 Door handle 30 B40497 Top rear panel 31 B40031 Gasket smoke outlet 32 B40047 Smoke outlet 33 B40054 02 Baffle assembly 7 required 34 B40043...

Page 29: ...PARTS LIST Model FLO115DABR C OLF140C12C B50042A 445 01 4054 06...

Page 30: ...rack 29 Z04F004 Paper filter 20 x 20 x 1 1 required 30 B40381 Blower door assembly Item 31 included 31 Z99F050 Acces door 32 B40356 Top back panel assembly 33 Z04F001 Paper filter 10 x 20 x 1 1 requir...