ICP DAS USA ZT-2018/S Quick Start Manual Download Page 6

 

ICP DAS, ZT-2018/S Quick Start, Version 1.0.0

   Page 6 

Copyright 

©

 2013 by ICP DAS Co., Ltd. All Rights Reserved. 

6

 Examples 

 

Configuring the ZT-2550/ZT-2570 

 

 

 

Configuring the 

ZT-2000 I/O Device 

 

 

Number 

Item 

Status  Description 

Address MSB 

OFF 

Address/Node ID is 01 (Rorary Switch=1) 

Protocol 

ON 

Use Modbus RTU Protocol 

Checksum 

OFF 

Disabled 

ZB PID 

OFF 

ZigBee Pan ID = 0x0000 

ZB Channel 

ON 

0x08 

ZigBee RF Channel = 0x0E 

ON 

0x04 

ON 

0x02 

OFF 

------ 

Data Format 

OFF 

Engineering Units Format 

10 

Type Code 

OFF 

AI Type Code = 0 (+/-15mV)   

11 

OFF 

12 

OFF 

 

 

         

1

                                       

2

                                     

3

                                     

4

                                     

5

                                       

6

                                       

7

                                   

8

                                       

9

                             

10

                       

11

                       

12 

Summary of Contents for ZT-2018/S

Page 1: ...n Utility on your Host PC to configure the ZT 2000 coordinator The utility can be founded on the CD in the Napdos ZigBee ZT_Series Utility folder or downloaded from http ftp icpdas com pub cd usbcd na...

Page 2: ...other modules on the same ZigBee network ZB Channel 0x00 0x01 0x0F Frequency MHz 2405 2410 2480 ZB channels 0x04 0x09 0x0E or 0x0F are recommended because they do not overlap with Wi Fi frequency ban...

Page 3: ...ary Switch 0 Software Config 1 2 3 F Note Address Note 1 01 02 03 0F MSB 0 Node ID Note 1 0x0001 0x0002 0x003 0x000F 0 1 2 3 F Address 10 11 12 13 1F MSB 1 Node ID 0x0010 0x0011 0x0012 0x013 0x001F No...

Page 4: ...o 0x1F 2 Protocol OFF DCON Protocol ON Modbus RTU Protocol 3 Checksum OFF Disabled DCON Protocol Only ON Enabled DCON Protocol Only 4 ZB PID OFF ZigBee Pan ID 0x0000 ON ZigBee Pan ID 0x0001 5 ZB Chann...

Page 5: ...the ZigBee Coordinator has been completed set the Pan ID and RF Channel values for the ZT 2000 I O device to the same values as the network and then reboot the device The module will automatically st...

Page 6: ...ice Number Item Status Description 1 Address MSB OFF Address Node ID is 01 Rorary Switch 1 2 Protocol ON Use Modbus RTU Protocol 3 Checksum OFF Disabled 4 ZB PID OFF ZigBee Pan ID 0x0000 5 ZB Channel...

Page 7: ...be used to simulate DCON Modbus communication This software can alse be used to verify the device settings and ZigBee I O functions The DCON Utility can be downloaded from http ftp icpdas com pub cd...

Page 8: ...positions A copy of the configuration file for the ZT 2000 coordinator This file can be obtained using the procedure outlined below and should be attached to your email a Set the DIP switch of the ZT...

Reviews: