Chapter 5
iCAM-7
60D User’s Manual ICP DAS
Appendix
96
5.2 How to let camera to do Hardware Reset
In some cases, such as user forget login username & password they’ve changed
before; or modify some settings to cause camera displayed image improperly; or
camera system is no response & hang to the user’s operation… etc., you may
need to let camera to do Hardware Reset. After that, camera could reboot,
operate and re-configure. The default iCAM setting after reset:
IP: 192.168.255.2
(Default Username/Password: admin/admin)
Submask: 255.255.0.0
Gateway address: 192.168.0.1
DNS Server address: 8.8.8.8
The hardware reset steps are as the following:
1)
Please make sure camera is power on first.
2)
Refer the below GPIO pin definition table; connect
Default Setting
and
GND
pins to short, remove the connection 10 seconds later.
3)
While RJ45 Green LED Indicator is flashing quickly, means camera
Hardware Reset Loading is processing now
……
Please don’t power off camera or do any unnecessary jobs during
this 3 minutes interval time;
camera would reboot and continue
streaming automatically.